CLEARANCE to Non-Combustible Construction:
A minimum of 16" clearance from the back of the grill to non-combustible construction is required for the
lid to open fully.
To Combustible Construction:
below the cooking surface, maintain a minimum of 16" from the sides and a minimum
of 14" from the back to adjacent vertical combustible construction.
Do not install this unit into combustible enclosures without an OCI insulated jacket!
LOCATION
When determining a suitable location take into account concerns such as exposure to wind, proximity to
traffic paths and keeping any gas supply lines as short as possible. Locate the grill only in a well ventilated area.
Never locate the grill in a building, garage, breezeway, shed or other such enclosed areas without an approved venti-
lation system. During heavy use, the grill will produce a lot of smoke.
Before any gas connections can be made, the cart must be assembled and the grill head mounted correctly
to the cart. Never connect an unregulated gas line to the appliance.
Main Burner
26" Grill
42000
32" Grill
56000
40" Grill
70000
L.P. TANK REQUIREMENTS
A dented or rusty L.P. tank may be hazardous and should be checked by your L.P. supplier. Never use a
cylinder with a damaged valve. The L.P. gas cylinder must be constructed and marked in accordance with the speci-
fications for L.P. gas cylinders of the U.S. Department of Transportation (DOT).The cylinder must be provided with
a shut off valve terminating in an L.P. gas supply cylinder valve outlet specified, as applicable, for connection type
Qcc1 in the standard for compressed gas cylinder valve outlet and inlet connection ANSI/CGA-V-1.
Manifold pressure: 11" W.C.
L.P. GAS HOOK-UP:
Ensure that the black plastic grommets are in place and that the hose does not come into contact with the
grill head or the heat shield.
CONNECTION:
Grill orifice for use with L.P. gas comes equipped with a high capacity hose/regulator assembly for
connection to a standard 20 lb. L.P. cylinder (18-1/4" high, 12-1/4" diameter).
Back Burner
The installation of this appliance must conform with local codes or, in the
absence of local codes, with the national fuel gas code, ANSI Z223.1a-
N/A
1988. Installation in Canada must be in accordance with the Standard
10,000
Can1-b149.1 and/or .2 (installation code for gas burning appliances and
10,000
equipment) and local codes.