OCI PRO-Performance Series -26BQP Use And Care Manual page 21

Table of Contents

Advertisement

Prepare a leak testing solution of soapy water by mixing in a spray bottle one part liquid soap to
one part water.
Make sure all the control knobs are in the OFF position.
Turn on the gas
 On Natural Gas systems, turn the main feed valve to the appliance.
 On LP systems, turn the cylinder valve knob counter clockwise one turn to open.
Apply the leak-testing solution by spraying it on joints of the gas delivery system.
Blowing bubbles in the soap solution indicates that a leak is present.
Stop a leak by tightening the loose joint resealing with thread sealant or Teflon tape, removing
sealant or tape in the event of a flared connection or by replacing the faulty part with a
replacement part recommended by the manufacturer. Do not attempt to repair the cylinder
valve if it is damaged. The cylinder must be discarded to a proper LP tank location and then
replaced.
Turn all control knobs back to the full OFF position.
If you are unable to stop a leak turn all control knobs back to the full OFF position, shut off the
gas supply to the appliance and release pressure in the hose and manifold by pushing in and
turning any of the control valves one quarter turn counter-clockwise.
On LP systems, remove the cylinder from the appliance.
Call an authorized gas appliance service technician or an LP gas dealer.
Do not use the appliance until the leak is corrected.