Bryant 313AAV Plus 80x Product Data page 9

4--way multipoise induced--combustion gas furnace
Table of Contents

Advertisement

DIMENSIONS
(733mm)
(664mm)
28-7/8"
26-1/8"
(FLUE COLLAR)
(641mm)
25-1/4"
22-9/16"
(573mm)
JUNCTION BOX
LOCATION
5-15/16"
(22mm)
7/8" DI A
ACCESSORY
1/2" DIA THERMOSTAT
WIRE ENTRY
3-15/16"
LEFT HAND GAS
ENTRY
33-5/16"
(846mm)
7/8" DIA. ACCESSORY
11/16"
(549mm)
(17mm)
21-5/8"
BOTTOM INLE T
24"
CASING
(610mm)
1. Two additional 7/8- -in. (22 mm) dia. knockouts are located in the top plate.
2. Minimum return- -air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer's recommendations for equivalent diameters.
3. Minimum return- -air opening at furnace.
a. For 800 CFM- -16- -in. (406 mm) round or 14- -1/2 x 12- -in. (368 x 305 mm) rectangle.
b. For 1200 CFM- -20- -in. (508 mm) round or 14- -1/2 x 19- -1/3 in. (368 x 491 mm)rectangle.
c. For 1600 CFM- -22- -in. (559 mm) round or 14- -1/2 x 22- -1/16- -in. (368 x 560 mm) rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets, a
combination of 1 side and the bottom, or the bottom of single side inlets. The use of both side inlets, a combination of one side and the bottom, or the bottom only
will ensure adequate return air openings for airflow requirements above 1800 CFM.
A
313AAV/JAV
CABINET
UNIT SIZE
WIDTH
IN (MM)
024045
14--- 3/16 (360)
048070
17--- 1/2 (445)
048090
21 (533)
060110
21 (533)
060135
24--- 1/2 (622)
1. 135 size furnaces require 5 ---in. (127 mm) vents. Use a 4 ---5 in. (102 ---127 mm) vent adaptor between furnace and vent stack.
2. See installation instructions for complete installation requirements.
A
D
F
24-7/8"
(632mm)
5-1/2"
E
(140mm)
1-11/16"
(43mm)
E
D
BOTTOM
SUPPLY WIDTH
RETURN WIDTH
IN (MM)
IN (MM)
12--- 9/16 (319)
12--- 11/16 (322)
15--- 7/8 (403)
16--- 1/8 (410)
19--- 3/8 (492)
19--- 1/2 (495)
19--- 3/8 (492)
19--- 1/2 (495)
22--- 7/8 (581)
23 (584)
2-7/16"
(62mm)
1-5/16"
(33mm)
13/16"
1-1/8"
(21mm)
(29mm)
4-13/16"
(122mm)
1/2" DIA. K.O.THERMOSTAT
WIRE ENTRY
8-9/16"
1-3/4" DIA.RIGHT HAND
(217mm)
GAS ENTRY
7/8" DIA. K.O. WIRE ENTRY
ALTERNAT E
(22mm)
JUNCTION BOX
LOCATIONS (TYP)
VENT OUTLE T
5 PLACES (TYP)
7/8" DIA. ACCESSORY
(22mm)
5-1/2"
(140mm)
1-1/2"
11/16"
3-3/4"
(17mm)
(95mm)
F
TOP VENT
CONNECTION
OUTLET
IN (MM)
(see Notes 1 & 2)
9--- 5/16 (237)
11--- 9/16 (294)
13--- 5/16 (338)
13--- 5/16 (338)
15--- 1/16 (383)
9
AIRFLOW
19"
13/16"
(483mm)
(21mm)
OUTLE T
9-5/8"
(13mm)
11/16"
7-3/4"
(17mm) (197mm) (244mm)
(44mm)
14-7/8"
(378mm)
(38mm)
1-1/4"
(32mm)
(560mm)
1"
22-1/16"
SIDE INLE T
(25mm)
A04037
VENT
MEDIA CABINET
SIZE
SIZE
IN (MM)
4
16 (406)
4
16 (406)
4
20 (508)
4
20 (508)
4 (Note 1)
24 (610)
11-1/2"
(292mm)