Bryant 313AAV Plus 80x Product Data page 6

4--way multipoise induced--combustion gas furnace
Table of Contents

Advertisement

SEE NOTES: 1,2,4,7,8,9
UPFLOW
SEE NOTES:1,2,3,4,5,7,8,9
DOWNFLOW
Venting Notes
1. For common vent, vent connector sizing and vent material: United States, latest edition of the National Fuel Gas Code (NFGC),
NFPA54/ANSI Z223.1. In Canada, latest edition of the National Standards of Canada, Natural Gas and Propane Installation Code
(NSCNGPIC), CSA B149.1- -00.
2. Immediately increase to 5- -in. vent connector outside furnace casing when 5- -in. vent connector required, refer to Note 1.
3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace, except when
KGAVG0101DFG is used in downflow position.
4. Type B vent where required, refer to Note 1.
5. 4 in. single wall vent must be used inside furnace casing and the KGAVG0101DFG Downflow Vent Guard Kit.
6. Accessory Downflow Vent Guard Kit, KGAVG0101DFG required in downflow installations with bottom vent configuration.
7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kit, KGACA02014FC and
KGACA02015FC for sizing and complete application details.
8. Secure vent connector to furnace elbow with (2) corrosion- -resistant sheet metal screws, space approximately 180_ apart.
9. Secure all other single wall vent connector joints with (3) corrosion- -resistant screws spaced approximately 120_ apart. Secure Type B
vent connectors per vent connector manufacturer's recommendations.
SEE NOTES: 1,2,3,4,7,8,9
A02058
SEE NOTES: 1,2,3,4,7,8,9
A02060
UPFLOW
A02059
DOWNFLOW
A02063
6
SEE NOTES: 1,2,4,5,7,8,9
DOWNFLOW
A02061
SEE NOTES: 1,2,4,5,6,7,8,9
DOWNFLOW
A02062