LG AMNW07GDBL1 Service Manual page 106

Lg multi-inverter type air conditioner svc manual(general)
Hide thumbs Also See for AMNW07GDBL1:
Table of Contents

Advertisement

Display
Title
code
67
Fan Lock Error
■ Error Diagnosis and Countermeasure Flow Chart
Is ODU Fan Motor Assemble
condition normal?
Yes
Is ODU Fan Motor normal?
Yes
Is wire connection of
ODU Fan Motor wire normal?
Yes
Is Inverter PCB assembly normal?
Yes
Recheck power and installation condition
Check Point
1. Check voltage between 1pin and 4pin of Fan Mortor connector (Tester diode mode)
2. Voltage value should be in 1V ±0.2V.
3. Do not replacing all of fan motor and PCB at once.
Check error code again, after replacing the abnormal part (Fan Motor or PCB) first.
Copyright ©2014 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Cause of error
Fan RPM is 10RPM or
less for 5 sec. when ODU
fan starts or 40 RPM or
less after fan starting.
Check ODU Fan Motor assemble condition and fan locking
No
→ Reassemble or replace if abnormality found
1. Set the multi tester to diode mode.
2. Check voltage between 1pin and 4pin of Fan Motor
No
(1 0.2V)
3. Replace Inverter PCB if abnormality found.
Check wiring between OUD fan motor and Inverter PCB
No
( Check if Hall Senor and Motor output terminal color is
matched)
→Reassemble if abnormality found
No
Replace Inverter PCB assembly
- 105 -
Part 5. Trouble Shooting
Check point & Normal condition
1. ODU fan locking
2. Heatsink assembly of INV PCB assemble condi-
tion abnormal
3. Defect of temperature sensing circuit part defect
of INV PCB