Install Decorative Front/Hood; Install Trim And/Or Surround; Air Shutter Setting - Heat&Glo 6000BEC-IPI Owner's Manual

Installation and operation
Table of Contents

Advertisement

H. Install Decorative Front/Hood
WARNING! Risk of Fire! Install ONLY doors or fronts
approved by Hearth & Home Technologies. Unapproved
doors or fronts could cause fi replace to overheat.
This fireplace has been supplied with an integral
barrier to prevent direct contact with the fi xed glass
panel. DO NOT operate the fi replace with the barrier
removed.
Contact your dealer or Hearth & Home Technologies if
the barrier is not present or help is needed to properly
install one.
1. Remove decorative front by lifting up and away from
appliance.
2. Install four shoulder bolts as shown in fi gure 14.3.
3. Hang decorative front onto shoulder bolts
4. Install Hood on appliance by inserting into the two hood
clips as shown in Figure 14.3.
Figure 14.3 Install Decorative Front and Hood
56
Heat & Glo • 6000BEC-IPI, 6000BEC-IPILP • 2187-900 Rev. K • 4/15
I. Install Trim and/or Surround
• Install optional trim kits and/or surrounds using the
instructions included with the accessory.
• Use non-combustible materials to cover the gap between
the sheet rock and the appliance (when applicable to the
model).
J. Air Shutter Setting
This appliance has an adjustable air shutter (which controls
the primary air) factory set for the minimum vertical vent
run. If your installation has more than the minimum required
vertical vent length, adjustment of the air shutter may
be necessary to obtain optimal fl ame appearance. This
should be adjusted by a qualifi ed installer at the time
of installation.
To adjust the air shutter, remove the burner and rotate
the shutter on the end of the burner neck. Care should be
taken when adjusting the air shutter so as not to cause
the appliance to soot. If sooting occurs the air shutter will
need to be rotated open.
Air Shutter Settings
Burner
SHIPPING HOOKS
NG
LP
3/8 in.
Full Open

Advertisement

Table of Contents
loading

This manual is also suitable for:

6000bec-ipilp

Table of Contents