Programming The Dispenser - Bunn LCA-1 Installation & Operating Manual

Hide thumbs Also See for LCA-1:
Table of Contents

Advertisement

PROGRAMMING THE DISPENSER

Two basic modes are available to the operator: Display Mode and Program Mode. Open the dispenser door to
access the digital Programming Switches with LED display. To enter the Display Mode, Set the RUN/NIGHT/
PROGRAM Switch to the RUN position.
Display Mode: Used to view the current set-up values. Use the MENU switch to scroll to the next display.
NOTE: The display blanks out after two minutes of inactivity. Press any button to activate the display.
LED DISPLAY
DISPLAY MODE
1 8 0
Home View
MENU
(-)
(+)
0 1 8 0
Tank Temperature
MENU
(-)
(+)
1
3
0
Dispense Ratio
MENU
(-)
(+)
2
0.
0
Portion Volume
MENU
(-)
(+)
3
0. 0
Dispense Total
MENU
(-)
(+)
4
O
F F
Rinse Alarm (Hrs)
MENU
(-)
(+)
XX.X
Software Version
MENU
(-)
(+)
DESCRIPTION
Displays Tank Temp only.
Displays Target Tank Temperature (F°)
Displays Dispense Ratio (XXX:1)
Displays Portion Dispense Volume
(XX.X Oz.).
Set to 0.0 to Disable.
Displays Total Coffee Concentrate
Dispensed (XX.X Gal)
Displays The Number Of Hours
Between Required Rinses.
(Default = OFF, Alarm Disabled)
Displays Software Version # -
Exits To Home View After 3 Seconds.
12
44806.1 020112
DIR Num: 44806.0001
PROGRAMMING THE DISPENSER (Cont.)
Program Mode
: Used to change or enter new set-up values.
To enter the Program Mode, Set the RUN/NIGHT/PROGRAM Switch to the PROGRAM position, the unit will
display "__PPP" to indicate it is in the Program Mode. Use the MENU switch to scroll to the next display. Use
the Increase (+) and Decrease (-) switch to adjust the values.
LED DISPLAY
PROGRAM MODE
0 1 8 0
Tank Temperature
MENU
(-)
(+)
1
3 0
Dispense Ratio
MENU
(-)
(+)
2
0.
0
Portion Volume
MENU
(-)
(+)
3
0.
0
Dispense Total
MENU
(-)
(+)
4
0.
0
Rinse Alarm Timer
MENU
(-)
(+)
Software Version
XX.X
MENU
(-)
(+)
08, October 2014
DESCRIPTION
Default = 180°F (82°C)
Range = 120° - 200°F (49 - 93°C)
Ready Temp = Tank Temp minus 10°F
(~5.5°C)
Set Coffee Mix Ratio
Default = 30:1
Range = 20 Max / 100 Min
Set Portion Dispense Volume
Default = 0.0, Disabled
Range = 5.0 - 40.0 Oz.
(.15 - 1.2 L)
Hold Decrease Switch to Reset Total
to Zero. 0.0 Gal (0.0 L)
Default = OFF (Rinse Alarm Disabled)
Range = 8 - 24 hrs
Displays Software Version # -
Exits To Home View After 3 Seconds.
13
44806.1 030612
RELEASED FOR PRODUCTION

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lca-1a

Table of Contents