5. Hold the charger firmly and pull out the battery
NOTE:
After operation, pull out batteries from the charger
first, and then keep the batteries properly.
Regarding electric discharge in case of new
batteries, etc.
As the internal chemical substance of new batteries
and batteries that have not been used for an extended
period is not activated, the electric discharge might
be low when using them the first and second time.
This is a temporary phenomenon, and normal time
required for recharging will be restored by recharging
the batteries 2-3 times.
How to make the batteries perform longer
(1) Recharge the batteries before they become completely
exhausted.
When you feel that the power of the tool becomes
weaker, stop using the tool and recharge its battery.
If you continue to use the tool and exhaust the electric
current, the battery may be damaged and its life will
become shorter.
(2) Avoid recharging at high temperatures.
A rechargeable battery will be hot immediately after
use. If such a battery is recharged immediately after
use, its internal chemical substance will deteriorate,
and the battery life will be shortened. Leave the battery
and recharge it after it has cooled for a while.
CAUTION:
If the battery is charged while it is heated because
it has been left for a long time in a location subject
to direct sunlight or because the battery has just
been used, the pilot lamp of the charger lights up
green. In such a case, first let the battery cool, then
start charging.
When the pilot lamp flickers in red (at 0.2-seconds
intervals), check for and take out any foreign objects
in the charger's battery connector. If there are no
foreign objects, it is probable that the battery or
charger is malfunctioning. Take it to your authorized
Service Center.
Since the built-in micro computer takes about 3
seconds to confirm that the battery being charged
with UC18YML2 is taken out, wait for a minimum of 3
seconds before reinserting it to continue charging. If
the battery is reinserted within 3 seconds, the battery
may not be properly charged.
Check the voltage of the in-car power source when
the pilot lamp flickers in green (every 0.2 seconds)
continuously.
If the voltage is 12V or lower, it indicates that the car
battery has weakened and cannot be charged.
If the pilot lamp does not blink in red (every second)
even though the charger cord or cigarette lighter
connecting plug is connected to the power, it indicates
that the protection circuit of the charger may be
activated.
Remove the cord or plug from the power and then
connect it again after 30 seconds or so. If this does
not cause the pilot lamp to blink in red (every second),
please take the charger to the Hitachi Authorized
Service Center.
53

PRIOR TO OPERATION

1. Preparing and checking the work environment
Make sure that the work site meets all the conditions
laid forth in the precautions.
2. Checking the battery
Make sure that the battery is installed firmly. If it is at
all loose it could come off and cause an accident.
3. Installing the bit (WH14DBAL2 / WH18DBAL2)
Always follow the following procedure to install driver
bit. (Fig. 5)
(1) Pull the guide sleeve away from front of the tool.
(2) Insert the bit into the hexagonal hole in the anvil.
(3) Release the guide sleeve and it returns to its original
position.
CAUTION:
If the guide sleeve does not return to its original
position, then the bit is not installed properly.
4. Selecting the socket matched to the bolt
(WR14DBAL2 / WR18DBAL2)
Be sure to use a socket which is matched to the bolt
to be tightened. Using an improper socket will not
only result in insufficient tightening but also in
damage to the socket or nut.
A worn or deformed hex. or square-holed socket will
not give an adequate tightness for fitting to the nut or
anvil, consequently resulting in loss of tightening
torque.
Pay attention to wear of socket hole, and replace
before further wear has developed.
5. Installing a socket (WR14DBAL2 / WR18DBAL2)
Select the socket to be used.
Pin, O-ring type
(1) Align the hole in the socket with the hole in the anvil
and insert the anvil into the socket.
(2) Insert the pin into the socket.
(3) Attach the ring to the groove on the socket.
Plunger type (Fig.6)
Align the plunger located in the square part of the
anvil with the hole in the hex. socket. Then push the
plunger, and mount the hex. socket on the anvil.
Check that the plunger is fully engaged in the hole.
When removing the socket, reverse the sequence.
Retaining ring type
(1) Align the square portions of the socket and the anvil
with each other.
(2) Make sure to firmly install the socket by pushing it all
the way into the anvil.
(3) When removing the socket, pull it out of the anvil.
CAUTION:
Please use the designated attachments which are
listed in the operations manual and Hitachi's catalog.
Accidents or injuries could result from not doing so.
Make sure to firmly install the socket in the anvil. If
the socket is not firmly installed it might come out
and cause injuries.

HOW TO USE

1. Check the rotational direction
The bit rotates clockwise (viewed from the rear side)
by pushing the R-side of the push button.
The L-side of the push button is pushed to turn the bit
counterclockwise. (See Fig. 7) (The
are provided on the body.)
R
L
and
marks