SECTION 5 ADJUSTMENT PROCEDURES

5-1 PREPARATION

When adjusting IC-M32, the optional CS-M32
EQUIPMENT
Output voltage
DC power supply
Current capacity
Measuring range
RF power meter
Frequency range
(terminated type)
Impedance
SWR
Frequency range
Frequency counter
Frequency accuracy : ±1 ppm or better
Sensitivity
Digital multimeter
Input impedance
I BEFORE ENTERING THE ADJUSTMENT MODE
• Cloning the adjustment frequency 156.800 MHz on the programmable CH.
(No select POC function POC ON on the adjustment frequency. )
I ENTERING THE ADJUSTMENT MODE
• Push and hold the [H/L] key and [PTT] switch, and then turn power ON.
I OPERATING IN THE ADJUSTMENT MODE
• Change adjustment items:
• Change adjustment values:
I EXITING THE ADJUSTMENT MODE
When adjustment is finished, need to do follow operation to cancel the adjustment mode. Otherwise, the transceiver does not
work properly.
• Turn power OFF.
• Push and hold the [H/L] key and [PTT] switch, and then turn power ON.
• DC POWER CABLE CONNECTION
DC power supply
CLONING SOFTWARE
GRADE AND RANGE
: 7.5 V DC
: 3 A or more
: 0.1–10 W
: 100–300 MHz
: 50 Ω
: Less than 1.2 : 1
: 0.1–300 MHz
: 100 mV or better
: 10 MΩ/DC or better
[16] key
[Y] and [Z] keys
connect (soldering)
+
+
connect (soldering)
line here
(Rev. 1.0 or later), OPC-478
EQUIPMENT
Frequency range
FM deviation meter
Measuring range
Frequency range
Audio generator
Measuring range
Frequency range
Standard signal
Output level
generator (SSG)
Power attenuation
Attenuator
Capacity
line here
Top view
5 - 1
are required.
CLONING CABLE
GRADE AND RANGE
: 30–300 MHz
: 0 to ±10 kHz
: 300–3000 Hz
: 1–500 mV
: 100–300 MHz
: 0.1 µV–32 mV
(–127 to –17 dBm)
: 40 dB or more
: 10 W or more