Maintenance; Safety Precautions; Visual Inspection; Routine Maintenance - Lincoln Electric FLEXTEC 450 Operator's Manual

Lincoln electric welding system user manual
Hide thumbs Also See for FLEXTEC 450:
Table of Contents

Advertisement

D-1

SAFETY PRECAUTIONS

WARNING
ELECTRIC SHOCK can kill.
• Only Qualified personnel should
perform this maintenance.
• Turn the input power OFF at the
disconnect switch or fuse box before
working on this equipment.
• Do not touch electrically hot parts.
------------------------------------------------------------------------
See additional warning information
throughout this Operator's Manual
-----------------------------------------------------------

VISUAL INSPECTION

Clean interior of machine with a low pressure air
stream. Make a thorough inspection of all compo-
nents. Look for signs of overheating, broken leads or
other obvious problems. Many problems can be
uncovered with a good visual inspection.

ROUTINE MAINTENANCE

1. Every 6 months or so the machine should be
cleaned with a low pressure airstream. Keeping
the machine clean will result in cooler operation
and higher reliability. Be sure to clean these areas:
• All printed circuit boards
• Power switch
• Main transformer
• Heatsink Fins
• Input rectifier
• Auxiliary Transformer
• Reconnect Switch Area
• Fan (Blow air through the rear louvers)
2. Examine the sheet metal case for dents or breakage.
Repair the case as required. Keep the case in good con-
dition to insure that high voltage parts are protected and
correct spacings are maintained. All external sheet
metal screws must be in place to insure case strength
and electrical ground continuity.

MAINTENANCE

PERIODIC MAINTENANCE
Thermal Protection
Thermostats protect the machine from excessive
operating temperatures. Excessive temperatures may
be caused by a lack of cooling air or operating the
machine beyond the duty cycle and output rating. If
excessive operating temperature should occur, the
thermostat will disable the machine output. The meter
will remain energized during this time. Thermostats
are self-resetting once the machine cools sufficiently.
If the thermostat shutdown was caused by excessive
output or duty cycle and the fan is operating normally,
the Power Switch may be left on and the reset should
occur within a 15 minute period.