Periodic Maintenance - Lincoln Electric OPTIMARC CV500 Service Manual

Table of Contents

Advertisement

SVM7007                                                                     MAINTENANCE                                                                                  C‐2 
 
SAFETY PRECAUTIONS 
Read  this  entire  section  of  the  operating  instructions 
before operating the machine. 
 
    WARNING 
ELECTRIC SHOCK can kill 
Only  qualified  personnel  should 
perform this installation. 
Turn the input power OFF at the main 
switch or fuse box before working on this equipment. 
Turn  off  the  input  power  to  any  other  equipment 
connected to the welding system at the main switch 
or fuse box before working on the equipment. 
 Do not touch electrically "Hot" parts. 
 Always  connect  the  OPTIMARC
(located  at  the  rear  of  the  case)  to  a  proper  safety 
(Earth)  ground. OPTIMARC
system with earthed neutral. 
 
    WARNING 
For  any  maintenance  or  repair  operation,  it  is 
recommended to contact the nearest technical service 
centre  or  directly  consult  the  machine  division  of  the 
Shanghai Lincoln Electric. 
Maintenance  or  repairs  performed  by  unauthorized 
service  centre  or  personnel  will  void  the 
manufacturer's warranty. 
 
 
 
 
 
®
  grounding  lug 
®
  is  for  use  on  a  4  wire 
 
OPTIMARC
PERIODIC MAINTENANCE 
The  daily  maintenance  frequency  of  the  equipment 
should be determined according to the actual working 
environment.  Any  noticeable  safety  hazard  should  be 
reported immediately. 
Check  to  make  sure  the  cable  and  related 
connectors work well, otherwise replace them. 
Clean interior of machine with a low pressure air 
stream regularly. 
Always  keep  the  machine  clean.  Use  a  soft  dry 
cloth  to  wipe  the  machine's  case,  especially  the 
louver part of air in and out. 
Do  not  open  or  connect  any  other  substance  into  the 
device. All maintenance work must be carried out when 
the  power  supply  of  the  equipment  is  cut  off.  Please 
wear  gloves  according  to  safety  rules.  The  operation 
safety  must  be  confirmed  before  each  repair  and 
welding test. 
 
THERMAL PROTECTION 
Thermostats  protect  the  machine  from  excessive 
operating temperatures. Excessive temperatures may be 
caused by a lack of cooling air or operating the machine 
beyond  the  duty  cycle  and  output  rating.  If  excessive 
operating temperature should occur, the thermostat will 
prevent output voltage or current. The meter will remain 
energized during this time. Thermostats are self‐resetting 
once  the  machine  cools  sufficiently.  If  the  thermostat 
shutdown was caused by excessive output or duty cycle 
and the fan is operating normally, the Power Switch may 
be left on. 
 
For  the  sake  of  safety,  when  the  torch  trigger  is  not 
released, the machine will not output again even after 
the thermostats are self‐reset. 
 
®
CV/CC500