23) Drive three (3) self-tapping screws into output
panel. (5/16" Nut driver or socket wrench).
NOTE: The CV outout terminal assembly mounts
under the weld output terminals on all machines.
24) With the CC/CV switch set to CC, start the engine
and check the open circuit voltage on the output
terminals. The voltage should be 80 to 100 volts
with the thermostat and range switch set at maxi-
mum. NOTE: OCV may be slightly higher when
the unit is cold. (Voltmeter)
25) Switch the CC/CV switch to CV and check the
voltage between the Positive output terminal and
the CV output terminal. The voltage should be 45
to 55 volts at maximum output position and 7 to
12 volts at minimum output position. (Voltmeter)
26) (For Classic II's only) Reassemble the side
panel. (3/8" Socket wrench)
– 15 –