Wire Feed Drive Roll Kits; 10 Series Wire Drive Roll Kit Installation; Gun And Cable Assemblies With Standard Connection; Gmaw Guns - Lincoln Electric LN-10 Operator's Manual

Heads & controls bench model
Hide thumbs Also See for LN-10:
Table of Contents

Advertisement

A-3

WIRE FEED DRIVE ROLL KITS

NOTE: The maximum rated solid and cored wire
sizes for each wire drive head and selected
drive ratio is shown on the SPECIFICATIONS
in the front of this section.
The electrode sizes that can be fed with each roll and
guide tube are stenciled on each part. Check the kit
for proper components.
10 Series Wire Drives use 4-Roll drive roll kits with 4
driven rolls, per Table C.1 in ACCESSORIES.
PROCEDURE TO INSTALL DRIVE
ROLL AND WIRE GUIDES
WARNING
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts such
as output terminals or internal wiring.
• When inching with gun trigger, electrode and
drive mechanism are "hot" to work and
ground and could remain energized several
seconds after the gun trigger is released.
• Turn OFF input power at welding power
source before installation or changing
drive roll and/or guide tubes.
• Welding power source must be connected
to system ground per the National
Electrical Code or any applicable local
codes.
• Only qualified personnel should
perform this installation.
Observe all additional Safety Guidelines detailed
throughout this manual.
------------------------------------------------------------------------

10 Series Wire Drive Roll Kit Installation

(KP1505 and KP1507)
1) Turn OFF Welding Power Source.
2) Pull open Pressure Door to expose rolls and wire
guides.
3) Remove Outer Wire Guide by turning knurled
thumb screws to unscrew from Feedplate.
4) Remove drive rolls, if any are installed, by pulling
straight off shaft. Remove inner guide.
5) Insert inner Wire Guide, groove side out, over the
two locating pins in the feedplate.
INSTALLATION
6) Install each drive roll by pushing over shaft until it
butts up against locating shoulder on the drive roll
shaft. (Do Not exceed maximum wire size rating of
the wire drive).
7) Install Outer Wire Guide by sliding over locating
pins and tightening in place.
8) Engage upper drive rolls if they are in the "open"
position and close Pressure Door.
TO SET IDLE ROLL PRESSURE, see "Idle Roll
Pressure Setting" in OPERATION.
GUN AND CABLE ASSEMBLIES
WITH STANDARD CONNECTION
The 10 Series Wire Drive Heads each require a
K1500 Gun Adapter installed See "Gun Adapters" in
ACCESSORIES section. The K1500-2 Gun Adapter
and Trigger Cable for Magnum 200-400 guns are fac-
tory included with the LN-10.

GMAW Guns

An expanding line of Magnum gun and cable assem-
blies are available to allow welding with solid and
cored electrodes using the GMAW process See the
appropriate Magnum literature for descriptions of the
200 to 550 ampere air cooled gun and cables that are
available. Gun cable lengths range from 10 ft. (3.0 m)
to 25 ft. (7.6 m) and feed electrode sizes .025" (0.6
mm) to 3/32" (2.4 mm). The entire line of Magnum
Fast-Mate gun and cable assemblies can also be
used by installing a K489-10 Fast-Mate adapter kit.
See "Gun and Cable Assemblies with Fast-Mate
Connection" in this section for details.

Innershield Guns

K126 and K115 gun and cable assemblies are avail-
able to allow welding with Innershield electrodes. Gun
cable lengths range from 10 ft. (3.0 m) to 15 ft. (4.5 m)
The 350 ampere K126 will feed electrode sizes .062
(1.6 mm) to 3/32" (2.4 mm). The 450 ampere K115
will feed 5/64" (2.0 mm) to 3/32" (2.4 mm) electrode.
Three smoke extraction gun and cable assemblies are
available, 250 ampere K309, 350 ampere K206 and
the 500 ampere K289. All gun cable lengths are 15 ft.
(4.5 m). These guns will feed electrode sizes .062"
(1.6 mm) to 3/32" (2.4 mm) and require the use of the
K184 vacuum unit for use with the LN-10.
LN-10
A-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

11368

Table of Contents