Download Print this page

GE AIR C18 Service Manual-Installation page 42

Split system air conditioner

Advertisement

Operating Procedures / Photos
Disassemble Axial Flow Fan
Use spanner to remove the nut at the fan to remove the
axial flow fan.
(refer to Figure 8-42)
Disassemble Outdoor Motor
Screw off the four tapping screws fixing the motor, pull
out the motor lead-out cable plug, and remove the motor.
Screw off the two tapping screws fixing the motor
support, and pull the motor support upward to remove it.
(refer to Figure 8-43)
Disassemble 4-Way Valve
Screw off the holding nut of the 4-way valve coil and
remove the coil. Use wet cotton cloth to wrap the 4-way
valve, unsold the four soldering points connecting the
4-way valve, and remove the 4-way valve. Be quick
during the unsoldering process, pay attention to keep the
wrapping cloth wet and do not allow the soldering flame
to burn the compressor lead-out cable.
(refer to Figure 8-44)
Screw
Screw
Motor
Screw Fixing
the Motor
Motor Support
Fixing Screw
4-Way Valve
39
Figure 8-42
Figure 8-43
Figure 8-44