Operating Procedures / Photos
Disassemble Filter, corner Inner Cover
and Stepping Motor
Screw off the screws and pull out the filter.
Use screwdriver to screw off the screws and remove
the angle inner cover.
Screw off the screw beside the stepping motor, turn
the stepping motor to a certain angle and then remove
the stepping motor. (refer to Figure 8-15, 8-16 and
8-17)
Disassemble Guide Louver
Lift the connecting rod and manually separate it from
the universal joint. Use screwdriver to unscrew the
connecting screws. (refer to Figure 8-18)
Screw
Figure 8-15
Figure 8-17
Figure 8-18
27
Filter
Screw
Figure 8-16
Stepping Motor
Screw
Universal Joint
Connecting Rod