Download Print this page

GE AIR C18 Service Manual-Installation page 29

Split system air conditioner

Advertisement

Operating Procedures / Photos
Disassemble Pump Drainage Pipe
Use wire cutter to cut the cable bundle, separate the pump drainage pipe and the pump water outlet, use
screwdriver to screw off the two screws beside the drainage pipe, then pull the pump drainage pipe
outward to remove it. (refer to Figure 8-10 and 8-11)
Liquid Level Switch
Pump
Pump Drainage Pipe
Figure 8-10
Screw
Disassemble Pump Assy,
Pump and Water Level Switch
Use socket wrench to twist off the nut beside
the pump assy, and then manually pull the
pump assy upward to remove it.
Use screwdriver to screw off the four screws
Figure 8-11
beside the pump.
Use screwdriver to screw off the two screws
beside the water level switch. (refer to Figure
8-12, 8-13 and 8-14)
Nut with Washer
Figure 8-12
Screw Pump
Screw
Water Level
Screw
Switch
Figure 8-13
Figure 8-14