Realignment; Clone Mode - Kenwood TK-3212 Service Manual

Hide thumbs Also See for TK-3212:
Table of Contents

Advertisement

TK-3212/3217

REALIGNMENT

1. Modes
User mode
PC mode

Clone mode

Self programming mode
Firmware version information
Mode
User mode
For normal use.
PC mode
Used for communication between the
transceiver and PC (IBM compatible).
Data programming
Used to read and write frequency data
mode
and other features to and from the
transceiver.
PC test mode
Used to check the transceiver using
the PC.
This feature is included in the FPU.
Clone mode
Used to transfer programming data
from one transceiver to another.
Self programming
You can program the frequency,
mode
signaling and other functions using
only the transceiver.
Firmware version
Used to confirm the internal firmware
information
version.
2. How to Enter Each Mode
Mode
User mode
PC mode
Clone mode
Self programming mode [S]+Power ON (Two seconds)
Firmware version
information
3. PC Mode
3-1. Preface
The TK-3212/3217 transceivers are programmed using a
personal computer, a programming interface (KPG-22) and
programming software (KPG-100D).
The programming software can be used with an IBM PC
or compatible. Figure 1 shows the setup of an IBM PC for
programming.
3-2. Connection procedure
1. Connect the TK-3212/3217 to the personal computer with
the interface cable.
2. When the POWER is switched on, user mode can be
entered immediately. When the PC sends a command,
the transceiver enters PC mode. In the PC mode,
"PROGRAM" is displayed on the LCD.
4
REALIGNMENT
Data programming
mode
PC tuning mode
PC test mode
Function
Operation
Power ON
Received commands from PC
[<B]+Power ON (Two seconds)
[Side1]+[Side2]+Power ON
(Two seconds)
When data is transmitting from the transceiver, the red
LED lights.
When data is received by the transceiver, the green LED
lights.
Notes:
• The data stored in the personal computer must match the
model type when it is written into the EEPROM.
• Change the TK-3212/3217 to PC mode, then attach the
interface cable.
3-3. KPG-22 description
(PC programming interface cable: Option)
The KPG-22 is required to interface the TK-3212/3217 with
the computer. It has a circuit in its D-subconnector (25-pin)
case that converts the RS-232C logic level to the TTL level.
The KPG-22 connects the SP/MIC connector of the TK-3212/
3217 to the computer's RS-232C serial port.
3-4. Programming software description
KPG-100D is the programming software for TK-3212/3217
supplied on a CD-ROM. This software runs under Windows
98, ME, Windows 2000 or XP on an IBM-PC or compatible
machine.
The data can be input to or read from TK-3212/3217 and
edited on the screen. The programmed or edited data can be
printed out. It is also possible to tune the transceiver.
IBM-PC
KPG-22
KPG-100D
RF Power meter
or SSG
Fig. 1
4. Clone Mode
4-1. Outline
"Clone Mode" copies the transceiver data to another
transceiver.
The dealer can copy the transceiver data to another
transceiver even without the use of a personal computer.
4-2. Example
The transceiver can copy the programming data to one or
more transceivers via RF communication.
The clone master and clone slave/s must be in Clone mode.
Gray
+
}
SP
Gray/Black
1.5D-XV Lead wire
+
}
MIC
1.5D-XV Shield wire –
Tuning cable
(E30-3216-05)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tk-3217

Table of Contents