4-3. Operation
1. To switch the clone slave/s to Clone mode, press and hold
the [<B] key while turning the transceiver power ON.
2. Wait for 2 seconds. "CLONE" appears on the LCD, followed
by "FRQTBL 1".
3. Select a channel table number using the [Selector] knob.
4. To switch the clone master to Clone mode, press and hold
the [<B] key while turning the transceiver power ON.
5. Wait for 2 seconds. "CLONE" appears on the LCD, followed
by "FRQTBL 1".
6. Select the same channel table number as the clone slave/s.
7. Press the [S] key on the clone master to begin data
transmission. When the clone slave starts to receive data,
the green LED will light and "CLONING" will appear on
the LCD. The master unit will display "MASTER".
8. When the clone master finishes sending data, a
"confirmation" tone will sound and "COMPLETE" will
appear on the LCD. If data transmission failed while cloning,
the Slave unit will produced an error tone and "CLONE
NG" will appear on the LCD.
9. If the cloning fails, no data will be available in the Slave unit
when it is returned to User mode.
10.When the cloning is successful, the Slave unit's "Scan" and
"Key lock" functions will return to their default values (Scan
= OFF, Key lock = OFF).
11.The master will remain in clone mode after cloning. The
slave unit will return to user mode after a successful cloning.
Notes:
• The dealer can clone data to two or more transceivers by
repeating the above procedures.
• If the transceivers Clone Mode is configured as "Disabled",
the transceiver cannot enter Clone mode.
• The table shown below will cover the frequency tables used
for wireless cloning.
• Clone mode cannot be entered in battery low state.
• A unit cannot be a "Master Unit" if it is unprogrammed. If
the [S] key is pressed, an "error" tone will sound.
• Once a unit is set to be the Master, it cannot be a slave
after the data has been transmitted. This protects the data
in the Master unit.
• MSK signaling is used in cloning.
• Electronic interface may cause a failure in data transfer
during Wireless Clone, such as when waveforms or
electromagnetics are being performed at the workbench.
• Clone mode can be used ONLY by the authorized service
personnel.
• The Clone mode setting must be configured as "Disable"
before being delivered to the end-user.
• To clone, replace the antenna from both the master
transceiver and the slave transceiver with a dummy
load.
• The transmit output power is automatically set to Low
in Clone mode.
REALIGNMENT
Cloning Frequency Table
MODEL
Type
Operating
Clone Frequency
Frequency (MHz)
Table
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
4-4. Adding the Data Password
If the Data password is set to the transceiver, you must
enter the password to activate a clone mode. The maximum
length of the password is 6 digits.
The following describes how to enter the password.
1. Press and hold the [S] key for 2 seconds while turning the
transceiver power on.
2. "CLN.LOCK.R"(When the Read authorization password is
set to the transceiver.) / "CLN.LOCK.W" (When the
Overwrite password is set to the transceiver.) is displayed
on the LCD.
3. If the [selector] knob is rotated while "CLN.LOCK.R"/
"CLN.LOCK.W" is displayed, the number (0 to 9) flashes
on the LCD.
When you press the [C>] key, the currently selected
number is determined.
If you press the [A] key, the least digit of the password is
deleted.
If you press the [S] key after entering the password in this
procedure, "FRQTBL 1" is displayed if the entered
password is correct.
I f t h e p a s s w o r d i s i n c o r r e c t , " C L N . L O C K . R " /
"CLN.LOCK.W" is redisplayed.
TK-3212/3217
TK-3212
K, M
K2, M2
450~490
470~512
450.000
470.000
452.000
472.000
454.000
474.000
456.000
476.000
458.000
478.000
460.000
480.000
462.000
482.000
464.000
484.000
466.000
486.000
468.000
488.000
470.000
490.000
472.000
492.000
474.000
494.000
476.000
496.000
478.000
498.000
480.000
500.000
482.000
502.000
484.000
504.000
486.000
506.000
488.000
508.000
TK-3217
M
440~480
440.000
442.000
446.000
448.000
450.000
452.000
454.000
456.000
458.000
460.000
462.000
464.000
466.000
468.000
470.000
472.000
474.000
476.000
478.000
480.000
5