Controls
Microphone
Speaker
PTT switch
Side 1 key
Side 2 key
■ Frequency and signaling
The transceiver has been adjusted for the frequencies
shown in the following table. When required, readjust them
following the adjustment procedure to obtain the frequencies
you want in actual operation.
Frequency (MHz) K, M type (TK-3212)
Channel No.
RX Frequency
1
470.050
2
450.050
3
489.950
4
470.000
5
470.200
6
470.400
Frequency (MHz) K2, M2 type (TK-3212)
Channel No.
RX Frequency
1
491.050
2
470.050
3
511.950
4
491.000
5
491.200
6
491.400
ADJUSTMENT
Channel selector
Power switch/
Volume control
Speaker/
Microphone
jacks
TX Frequency
470.100
450.100
489.900
470.000
470.200
470.400
TX Frequency
491.100
470.100
511.900
491.000
491.200
491.400
TK-3212/3217
Frequency (MHz) M type (TK-3217)
Channel No.
RX Frequency
1
460.050
2
440.050
3
479.950
4
460.000
5
460.200
6
460.400
Signaling
Signaling No.
RX
1
None
2
None
3
QT 67.0Hz
4
QT 151.4Hz
5
QT 250.3Hz
6
DQT D023N
7
DQT D754I
8
DTMF 159D
9
None
10
None
■ Preparations for tuning the transceiver
Before attempting to tune the transceiver, connect the unit
to a suitable power supply.
Whenever the transmitter is tuned, the unit must be
connected to a suitable dummy load (i.e. power meter).
The speaker output connector must be terminated with a
8Ω dummy load and connected to an AC voltmeter and an
audio distortion meter or a SINAD measurement meter at all
times during tuning.
Adjustment Frequency
K, M type (TK-3212)
TEST CH
RX Frequency
Center
470.050MHz
Low
450.050MHz
High
489.950MHz
Low'
460.050MHz
High'
480.050MHz
K2, M2 type (TK-3212)
TEST CH
RX Frequency
Center
491.050MHz
Low
470.050MHz
High
511.950MHz
Low'
480.550MHz
High'
501.550MHz
TEST CH
RX Frequency
Center
460.050MHz
Low
440.050MHz
High
479.950MHz
Low'
450.050MHz
High'
470.050MHz
TX Frequency
460.100
440.100
479.900
460.000
460.200
460.400
TX
None
100Hz Square Wave
QT 67.0Hz
QT 151.4Hz
QT 250.3Hz
DQT D023N
DQT D754I
DTMF 159D
DTMF tone 9
MSK
TX Frequency
470.100MHz
450.100MHz
489.900MHz
460.100MHz
480.100MHz
TX Frequency
491.100MHz
470.100MHz
511.900MHz
480.600MHz
501.600MHz
M type (TK-3217)
TX Frequency
460.100MHz
440.100MHz
479.900MHz
450.100MHz
470.100MHz