Kenwood TK-3212 Service Manual page 31

Hide thumbs Also See for TK-3212:
Table of Contents

Advertisement

Item
Condition
2.Sensitivity
TEST CH: Low
check
Center
[Wide]
High
SSG otuput:–117 dBm(0.3µV) AF VTVM
SSG MOD:3.0kHz
[Narrow]
TEST CH:Center
SSG otuput:–115 dBm(0.4µV)
SSG MOD:1.5kHz
3.SQL1
TEST CH: Center
(Threshold)
Low
writing
High
[Wide]
SSG otuput:–123 dBm(0.16µV)
SSG MOD:3.0kHz
[Narrow]
TEST CH: Center
SSG otuput:–122 dBm(0.18µV)
SSG MOD:1.5kHz
4.SQL9
TEST CH: Center
(Tight)
Low
writing
High
[Wide]
SSG otuput:–117 dBm(0.3µV)
SSG MOD:3.0kHz
[Narrow]
TEST CH: Center
SSG otuput:–116 dBm(0.35µV)
SSG MOD:1.5kHz
5.BATT
BATT terminal voltage:5.75V DVM
Detection
Writing
ADJUSTMENT
Measurement
Test equipment
Terminal
SSG
ANT
DVM
Oscilloscope
ANT
BATT terminal
TK-3212/3217
Adjustment
Parts
Method
Check
Programming
Write
Software:
KPG-100D
Write
Specifications/
Remarks
12dB SINAD or more
Squelch open
BATT terminal
voltage:5.75V