Technical Data Table
Model
Dimensions 40° sloping roof (LxDxH)
Dimensions fl at roof (LxDxH)
Gross area
Opening area
Absorber area
Total weight
Empty weight
Primary circuit water content
Number of collectors
Hot water tank volume
Hot water tank treatment
Hot water tank cathode protection
Electrical heating element
Solar circuit connections size
DHW circuit connections size
Solar circuit max. operating pressure (safety valve)
DHW circuit max. operating pressure
DHW circuit max. operating temperature
Absorber in copper with high selectivity treatment
Degree of absorption
Emissivity
Insulation in high-density rock wool of thickness
Extra clear prismatic glass of thickness
Transmittance
Climatic conditions of the test for protection against overtemperature in conformity with class b accord-
ing to table 3 of Standard ISO 9806-2
SIS. ECOTECH
2 F 160
mm
1350 X 2300 X 600
mm 1350 X 1700 X 1850
m2
1.97
m2
1.89
m2
1.87
kg
265
kg
100
L
15
no.
1
L
160
W
1500
ø
3/4"
ø
3/4"
kPa
180
kPa
850
°C
90
%
95
%
5
mm
40
mm
4
%
91.4
Code 3541B140 - 11/2011 (Rev. 00)
SIS. ECOTECH
SIS. ECOTECH
2 F 220
2 F 280
1450 X 2600 X 600
2500 X 2300 X 600
1450 X 1900 X 2100
2500 X 1700 X 1900
2.32
2.23
2.21
350
125
20
1
220
Porcelain enamelled
Magnesium anode
1500
1500
3/4"
3/4"
180
850
90
95
5
40
4
91.4
GB
3.94
3.78
3.74
465
175
24
2
280
3/4"
3/4"
180
850
90
95
5
40
4
91.4
55