Clearances To Combustibles - Heatilator CD4236-MOD Installation Manual

Hide thumbs Also See for CD4236-MOD:
Table of Contents

Advertisement

B. Clearances to Combustibles
When selecting a location for the appliance it is important
to consider the required clearances to walls (see Figure
3.5).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be lo-
cated out of traffi c and away from furniture and draperies.
NOTE: THE REAR STANDOFF MAY NEED
TO BE REMOVED WHEN VENTING AT 45º
F
1/2 IN.
A
CD4236-MOD
CD4842-MOD
Figure 3.5 Appliance Locations
Heatilator • CD4236-MOD, CD4842-MOD Installation Manual • 2241-901 Rev. C • 6/15
A
B
C
TOP VENT
ONE 90º ELBOW
A
B
in.
51
42
mm
1295
1067
in.
55-7/8
49
mm
1419
1245
NOTICE: Illustrations refl ect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
B
ALCOVE
D
INSTALLATION
B
E
C
D
72
See Section 10.C.
Mantel Projections
1829
79
See Section 10.C.
Mantel Projections
2007
E
F
22
17-3/4
559
451
22
19-3/4
559
502
11