B. Appliance Location and Clearances to
Combustibles
When selecting a location for the appliance it is important
to consider the required clearances to walls and allow suf-
ficient clearance for heat management systems venting.
See Figure 3.8 and Figure 3.9.
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be located
out of traffic and away from furniture and draperies.
E
G
A
Model
Inches
CRAVE4836-C
Millimeters
Inches
CRAVE6048-C
Millimeters
Inches
CRAVE7260-C
Millimeters
Inches
CRAVE8472-C
Millimeters
Figure 3.8 Appliance Locations: CRAVE-C Single-Sided Models
18
Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21
G
B
C
Refer to Section 10 for hearth, mantel and
wall projection information.
If a Heat Management System will be
installed, refer to Section 6.B for information.
B
A
B
62-1/2
48-1/4
1588
1226
70-3/4
60-1/4
1797
1530
79-1/2
72-1/4
2019
1835
88
84-1/4
2235
2140
NOTICE: Illustrations reflect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
B
18 in. (457 mm) required when Passive Heat Side
Discharge Kit is installed. Refer to the Passive
Heat kit instructions for more information.
F
C
D
88-1/8
2238
100-3/8
See
Section
2550
10, Figure
112-3/8
10.17 and
2854
10.18.
124-3/8
3159
E
F
G
24-1/2
18-3/4
1
622
476
25
28-1/2
18-3/4
1
724
476
25
31-3/4
18-3/4
1
807
476
25
35-1/4
18-3/4
1
895
476
25
D
H
H
50
1270
62
1575
74
1880
86
2184