C-8
CONNECTION OF THE K488 SG CONTROL
MODULE AND K487 MAGNUM SPOOL GUN
TO THE SA-250 (SEE FIGURE C.5.)
1. Shut the welder off.
2. Connect the electrode cable from the SG Control
Module to the "+" terminal of the welder. Connect
the work cable to the "CV–" terminal of the welder.
NOTE: Welding cable must be sized for current
and duty cycle of application.
NOTE: Figure C.5 shows the electrode connected
for positive polarity.
To change polarity, shut the
welder off and reverse the electrode and work cables
at the SA-250 output terminals.
3. Connect the K867 Universal adapter to the K492
input cable as shown in Figure C.5. Connect the
other end of the adapter to the 14 pin amphenol on
the SA-250.
4. Connect the K492 Input Cable to the SG Control
Module.
5. Set the slide switch on the SG Control Module to
the "Lincoln" position.
CAUTION
Be sure this switch is set to the "Lincoln" (contact clo-
sure) position before attempting to operate the SG
Control Module. Incorrect switch position could result
in damage to the SG Control Module and/or the SA-
250.
SA-250/K492/K488/K487 SPOOL GUN CONNECTION DIAGRAM
ACCESSORIES
FIGURE C.5
14 PIN
AMPHENOL
+
CV-
TO
K867 UNIVERSAL
WORK
ADAPTER PLUG
ELECTRODE CABLE TO
K438 SG CONTROL CABLE
SA-250
6. Place the IDLER switch on the SA-250 in the
"HIGH" position.
CAUTION
Any increase of the high idle engine RPM by changing
the governor setting or overriding the throttle linkage
will cause an increase in the AC auxiliary voltage. If
this voltage goes over 140 volts, wire feeder control
circuits may be damaged. The engine governor set-
ting is preset at the factory — do not adjust above
RPM specifications listed in this manual.
7. Adjust wire feed speed at the SG Control Module.
NOTE: For remote control, a K775 remote control is
required.
CAUTION
When the welder is in local control, the electrode is
always "HOT."
SPARE
82
Insulate Each
K488 SG
81
Unused Lead
CONTROL
42
Individually
MODULE
41
21
31
31
32
32
2
2
K492
4
4
INPUT CABLE
GND
GND
GREEN
75
75
76
76
77
77
K775 OPTIONAL
Splice Leads
REMOTE CONTROL
and Insulate