Welder/Generator Maintenance; Storage; Cleaning; Brush Removal And Replacement - Lincoln Electric RANGER 305LPG IM10043-A Operator's Manual

Lincoln electric welder user manual
Table of Contents

Advertisement

D-5

Welder/Generator Maintenance

STORAGE: Store the RANGER® 305LPG in clean,
dry protected areas.
CLEANING: Blow out the generator and controls peri-
odically with low pressure air. Do this at least once a
week in particularly dirty areas.
bRUSH REMOVAL AND REPLACEMENT: It's nor-
mal for the brushes and slip rings to wear and darken
slightly. Inspect the brushes when a generator over-
haul is necessary.
CAUTION
Do not attempt to Polish slip rings while the
engine is running.
WARNING
Service and Repair should only be performed by
Lincoln Electric Factory Trained Personnel.
Unauthorized repairs performed on this equip-
ment may result in danger to the technician and
machine operator and will invalidate your factory
warranty. For your safety and to avoid Electrical
Shock, please observe all safety notes and pre-
cautions.
-----------------------------------------------------------------------
MAINTENANCE
GFCI RECEPTACLE TESTING AND RESET-
TING PROCEDURE
The GFCI receptacle should be properly tested at
least once every month or whenever it is tripped. To
properly test and reset the GFCI receptacle:
• If the receptacle has tripped, first carefully remove
any load and check it for damage.
• If the equipment has been shut down, it must be
restarted.
• The equipment needs to be operating at high idle
speed and any necessary adjustments made on the
control panel so that the equipment is providing at
least 80 volts to the receptacle input terminals.
• The circuit breaker for this receptacle must not be
tripped. Reset if necessary.
• Push the "Reset" button located on the GFCI recep-
tacle. This will assure normal GFCI operation.
• Plug a night-light (with an "ON/OFF" switch) or other
product (such as a lamp) into the GFCI receptacle
and turn the product "ON".
• Push the "Test" button located on the GFCI recepta-
cle. The night-light or other product should go
"OFF".
• Push the "Reset" button, again. The light or other
product should go "ON" again.
If the light or other product remains "ON" when the
"Test" button is pushed, the GFCI is not working prop-
erly or has been incorrectly installed (miswired). If
your GFCI is not working properly, contact a qualified,
certified electrician who can assess the situation,
rewire the GFCI if necessary or replace the device.