T2 Auxiliary Transformer Test - Lincoln Electric PRO-CUT SVM146-A Service Manual

Lincoln electric welder user manual
Table of Contents

Advertisement

F-27
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or
machine operator and will invalidate your factory warranty. For your safety and to avoid elec-
trical shock, please observe all safety notes and precautions detailed throughout this manu-
al.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
DESCRIPTION
The test will determine if the auxiliary transformer is functional when the correct primary volt-
age is applied to the primary winding.
MATERIALS NEEDED
Volt/ohmmeter
Machine wiring diagram
5/16" Nut driver
230 VAC isolated power supply
This procedure takes approximately 18 minutes to perform.
TROUBLESHOOTING & REPAIR
(T2) AUXILIARY TRANSFORMER TEST
WARNING
PRO-CUT 80
F-27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pro-cut 80

Table of Contents