INTELIA

5.1.1. Intelia Cappuccino test mode

To enter Test Mode
1.
Hold down the buttons Espresso
and Menu.
2.
Turn on the main switch at the
rear of the machine
Entry into Test Mode results in a screen divided into sections, as illustrated in the diagram below.
Entry into Test Mode results in a screen divided into sections, as illustrated in the diagram below.
Press STAND_BY "
Press STAND_BY "
The letter next to it changes from N to Y when only one button is pressed.
The letter next to it changes from N to Y when only one button is pressed.
By pressing buttons 1, 3, 4, 6 the display color changes from GREEN to RED.
By pressing buttons 1, 3, 4, 6 the display color changes from GREEN to RED.
By pressing buttons 2, 5 and 7 the display color changes from GREEN to
By pressing buttons 2, 5 and 7 the display color changes from GREEN to
YELLOW.
YELLOW.
Button 4 must be pressed at the end only once, since pressing it moves on to
Button 4 must be pressed at the end only once, since pressing it moves on to
the next page.
the next page.
ERROR condition:
ERROR condition:
The letters do not change from N to Y or are always Y, in this case check the fl at communication
The letters do not change from N to Y or are always Y, in this case check the fl at communication
cable with the Control Board/Power Board, if it does not change color check the cable JP4 too.
cable with the Control Board/Power Board, if it does not change color check the cable JP4 too.
Press STAND_BY "
Press STAND_BY "
Initial status.
Initial status.
Insert full water tank
Insert full water tank
The TANK-H20 indicator must change from "N" to "Y"
ERROR Condition:
ERROR Condition:
If the indication does not change, check the capacitive sensor and relative wiring
If the indication does not change, check the capacitive sensor and relative wiring
(JP23).
(JP23).
Insert the dreg drawer
Insert the dreg drawer
The DREG indicator must change from "N" to "Y"
The DREG indicator must change from "N" to "Y"
ERROR Condition:
ERROR Condition:
If the indication does not change, check the microswitch on the dreg drawer
If the indication does not change, check the microswitch on the dreg drawer
and relative wiring (JP16).
and relative wiring (JP16).
Saeco International Group
Firmware Software version
Firmware Software version
Shows the version of the fi rmware loaded and the internal checksum (it
Shows the version of the fi rmware loaded and the internal checksum (it
gives univocal traceability)
gives univocal traceability)
" to move to the next screen
" to move to the next screen
Operational check – keys
Operational check – keys
Initial status
Initial status
" to move to the next screen
" to move to the next screen
Operational check microswitches and sensors
Operational check microswitches and sensors
Rev. 02 / September 2012
05 TROUBLESHOOTING
1
2
Page
01
/ 22

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents