Wiring Diagram - Lincoln Electric PRO-CUT 10474 Operator's Manual

Lincoln electric welder user manual
Hide thumbs Also See for PRO-CUT 10474:
Table of Contents

Advertisement

E-3
PROBLEMS
(SYMPTOMS)
The Pro-Cut powers up properly but
there is no response when the trig-
ger is pulled and only the POWER
LED is lit.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
POSSIBLE AREAS OF
MISADJUSTMENTS(S)
1. Press Purge button on the front of
the Pro-Cut. If air does not flow,
then:
a. Auxiliary transformer may be
faulty.
b. The main gas solenoid assem-
bly may be faulty. Check or
replace.
c. Possible faulty Output Power
board.
d. Possible faulty Control board.
2. (check for continuity from the bulk-
head connector to the molex) See

Wiring Diagram.

3. Remove the handles (or barrel) of
the torch and examine all the con-
nections. Pay attention to location
of electrode lead mounting at back
of torch head, broken trigger and
solenoid leads.
4. Check for proper trigger switch
operation. Remove the torch cable
assembly from the Pro Cut and
test for continuity between 9 and 1
at the quick connect when the trig-
ger switch is depressed and no
continuity when the switch is not
depressed. Replace the trigger
switch or torch cable if defective.
5. Possible faulty Control board.
6. Possible faulty Output Power
board.
PRO-CUT 55
If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized
Field Service Facility.
CAUTION
RECOMMENDED
COURSE OF ACTION
E-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pro-cut 10473Pro-cut 10475Pro-cut 10476Pro-cut 55

Table of Contents