  • Page 1 P 227 - P 229 - PH 227 - PH 233 GEBRAUCHSANWEISUNG INSTRUCCIONES DE USO MANUEL D'UTILISATION OPERATING MANUAL ISTRUZIONI D’USO > GEBRUIKSAANWIJZING KULLANIM KILAVUZU...
  • Page 2 ALLGEMEINE SICHERHEIT Aus Sicherheitsgründen bitten wir Sie, die Bedienungsanleitung vor Inbetriebnahme sorgfältig zu lesen! Personen, die mit der Bedienungsanleitung nicht vertraut sind, dürfen das Gerät nicht bedienen. A. Kein beschädigtes Kabel verwenden. G. Nicht in Wasser eintauchen. B. Kabel nicht zusammendrücken oder knicken. H.
  • Page 3 SICUREZZA > Per motivi di sicurezza, si raccomanda di leggere attentamente il manuale prima di utilizzare l’apparecchio. Le persone che non conoscono il funzionamento del climatizzatore non devono usarlo. Si raccomanda di riporre il manuale in un luogo sicuro per future referenze. A.
  • Page 4 IMPORTANT COMPONENTS ³ Remote control · Control panel » Air outlet Air inlet ´ Filter holder Air filters (activated carbon + Bacterio-static 3M HAF filter) Air duct (2x) Water drain Drainage point (PH227 + PH233) µ Handles ¸ Hose connector (4x) ¹...
  • Page 5 Dear Sir, Madam, Congratulations on the purchase of your Zibro air conditioner. This air conditioner has five functions in addition to cooling the air, namely heating (for PH 227 + PH 233 only), air dehumidification, circulation and filtration as well as purification of air by it’s unique sterionizer bi-polar ionisation.
  • Page 6: Safety Regulations

    SAFETY REGULATIONS IMPORTANT • The installation must be completely in accordance with local regulations, ordinances and standards. • The device is suitable exclusively for use in dry places, indoors. • Check the mains voltage. This device is suitable exclusively for earthed sockets –...
  • Page 7: Installation

    • Children should be supervised to ensure that they do not play with the appliance. ATTENTION! • Never use the device with a damaged cable or plug. Never allow the cable to be pinched off or come into contact with sharp edges. •...
  • Page 8 Models are fitted with the EVS (Effective Ventilation System) as standard. The second hose must be attached in order to utilise this option. Attach the hose connectors ¸ and the hose adapter as described above. ATTENTION! The device can be used with 1 or with 2 hoses. If the device is used with 2 hoses, it may fall into a different Energy Efficiency Class.
  • Page 9 OPERATION / REMOTE CONTROL ATTENTION! • Avoid the remote control from getting wet. Remove it from the unit when condensation can occur. LCD display Timer/Clock On/off Fan speed Low noise Function Sterionizer selector switch Down Signal indicator Clock Sterionizer function indicator Ventilator speed indicator Timer setting indicator Timer on/off...
  • Page 10 PLACING BATTERIES IN THE REMOTE CONTROL Remove the battery cover by pressing the lips in and then pulling the cover toward you. Place the new batteries as indicated (pay attention to the plus- (+) and minus poles (-). Now replace the battery cover. NOTE! Use 2 AAA (1.5 Volt) batteries.
  • Page 11 STERIONIZER FUNCTION Press Sterionizer function to start the function and press again to stop it. Positive nd negative ions are generated in every operating mode. LOW NOISE BUTTON During unit operation. Press low noise button , unit operates at low noise. Press the button again to cancel the low noise setting and return to the previous setting.
  • Page 12 water will be removed through the hose. The maximum rise may be 1.5 m from the floor on which the device is standing. Exceeding this distance may damage the machine or cause leaks. During the dehumidification, the ventilator speed can not be adjusted when room temperature is below 25°C.
  • Page 13: Air Filter

    switch on or off. Switching off The timer OFF function can be set when the airconditioner is switched on: • Press button • Set the number of hours desired (1-12) with the aid of • Press to save Switching on Default temperature setting is 24°C.
  • Page 14 Wire mesh filter to remove coarse dust particles. Bacterio-static 3M HAF filter to remove particles from the air such as pollen, animal dander and dust. Activated carbon filter to remove odours. The mesh filter is part of the filter holder. The filter holder can be opened. The activated carbon filter and the Bacterio-static 3M HAF filter can be removed.
  • Page 15: Emptying The Water Reservoir

    • Filter packages are available at your dealer. • Only use suitable Zibro filters. This will prevent any damage to your airconditioner. Using other than the original filters is entirely at the risk of the consumer. This may have a negative effect on the operation of the device and may result in damage.
  • Page 16: Maintenance

    Lead the other end of the water drain hose to suitable place (drain/sink). Ensure that the drain hose is not twisted or kinked. ATTENTION! The hose must be descending along its entire length. MAINTENANCE ATTENTION! First switch the device off and pull the plug out of the socket before you clean the device or filter or when you replace the filters.
  • Page 17: Problems And Solutions

    PROBLEMS AND SOLUTIONS Problem Cause Solution The device does not work and the transparent 1/2 - The internal water Empty the internal water ring around the button on reservoir is full. reservoir (see chapter E). the front of the device flashes RED.
  • Page 18: Guarantee Conditions

    The shipping costs of the airconditioner or parts and the related risk are always borne by the purchaser. Damage, caused by not using suitable Zibro filters falls outside the guarantee. To prevent unnecessary costs, we recommend that you always first read the instructions carefully.
  • Page 19: Technical Specifications

    TECHNICAL SPECIFICATIONS Use indicatively, subject to change. Model P 227 PH 227 P 229 PH 233 Cooling capacity* 2700 2700 2900 3300 EE Class EER* 2,62 2,62 Heating capacity* 2700 3150 Heating performance COP* 2,61 2,61 Power consumption 1,03 1,03...
  • Page 20 Jos haluat huoltoapua, lisätietoja tai laitteen kanssa tulee ongelmia, tutustu verkkosivustoon osoitteessa www.zibro.com tai kysy neuvoa PVG kuluttajapalvelukeskuksesta (www.zibro.com). If you need information or if you have a problem, please visit the our website (www.zibro.com) or contact our sales support (you find its phone number on www.zibro.com) Per informazioni e in caso di problemi, visitate il sito Web www.zibro.com oppure contattate il Centro Assistenza Clienti (per conoscere il numero...