  • Page 1 P 820 - P 828 - P 832 BEDIENUNGSANLEITUNG BRUGSANVISNING INSTRUCCIONES DE USO MANUEL D'UTILISATION OPERATING MANUAL > ISTRUZIONI D’USO GEBRUIKSAANWIJZING INSTRUKCJA OBS UGI 1 0 2 KULLANIM KILAVUZU 1 1 6...
  • Page 2: Allgemeine Sicherheit

    ALLGEMEINE SICHERHEIT Aus Sicherheitsgründen bitten wir Sie, die Bedienungsanleitung vor Inbetriebnahme sorgfältig zu lesen! Personen, die mit der Bedienungsanleitung nicht vertraut sind, dür- fen das Gerät nicht bedienen. A. Kein beschädigtes Kabel verwenden. G. Nicht in Wasser eintauchen. B. Kabel nicht zusammendrücken oder knicken. H.
  • Page 3: General Safety

    GENERAL SAFETY For safety reasons, please read this manual carefully before operating. Persons who are not familiar with this manual must not use this air conditioner. We strongly recommend keeping this manual in a safe place for future reference. A. Do not use a damaged cable. G.
  • Page 4: Important Components

    IMPORTANT COMPONENTS Control Panel Air outlet Carrying handle Caster wheels Water container Air filter Air inlet Exhaust air outlet Cord storage Water stopper / drainage point Hose Hose connector (optional) Hose adapter (optional) Caps for hose adapter (optional) Remote control Slidebar connector (optional) Telescopic slidebar...
  • Page 5 Dear Sir, Madam, Congratulations on the purchase of your air conditioner. In addition to air cooling, this air conditioner has three other functions: air dehumidification, air circulation and air filtration. The mobile air conditioner is easy to operate and move. You have acquired a high quality product that will provide you with many years of pleasure, on condition that you use it responsibly.
  • Page 6: A Safety Instructions

    SAFETY INSTRUCTIONS Install the device only when it complies with local regulations, by-laws and s t a n d a rds. The unit is only suitable for use in dry locations, indoors. Check the mains voltage and fre q u e n c y. This unit is only suitable for earthed sockets, connection voltage 220-240 V.
  • Page 7  AT T E N T I O N ! • Never use the device with a damaged power cord, plug, cabinet or control panel. Never trap the power cord or allow it to come into contact with sharp edges. •...
  • Page 8 Fit the telescopic slide bar to the window and adjust the length. Put the slidebar connector in the opening in the telescopic slide bar. Close the window or door as much as possible to prevent outside air entering the room. Ensure that the slidebar connector has a free flow outside.
  • Page 9 4. MODE SWITCH Push the button successively until the icon re p resenting the desired mode is appearing (=> Cool => Fan => Cool => etc). On the LCD-display you will see: Cooling Fan only Each time the unit starts, it starts operating in coolmode with a set temperature of 22°C.
  • Page 10 Programming the timer for OFF - when the unit is running. 88:88 P ress the push button; the 2 left digits of the 4 digits on the LCD display are flashing. Press to adjust the hour. 88:88 Press the push button again, the 2 right digits of the 4 digits are flashing. Press to adjust the minutes of the clock in intervals of 5 minutes.
  • Page 11 Press to adjust the hour. 88:88 Press the push button again, the 2 right digits of the 4 digits are flashing. Press to adjust the minutes of the clock in intervals of 5 minutes. The timer is set. After 10 seconds the time display returns. Repeat the above pro c e d u re while the digits are still flashing for setting the OFF.
  • Page 12 11. DEHUMIDIFICATION If the unit will be used mainly as dehumidifier, do not connect the exhaust hose and let the warm air re t u rn in the room. Continuous drainage is then necessary and more efficient. For continuous drainage: Switch off the unit and remove the plug from the mains Remove the water stopper and rubber plug Connect a drain tube (ø...
  • Page 13 In that case, airborne fig. 4 micro-organisms are not neutralised and unpleasant odours are not removed. • Only use suitable Zibro filters. This will prevent damage to your airconditioner. • Suitable filter packages are available at your dealer.
  • Page 14: Remote Control

    EMPTY INTERNAL WATER CONTA I N E R Under extreme (humidity) circumstances it may be necessary to empty the internal water container. When the internal water container is full the backlight on the LCD-display will be flashing. The unit will switch off automatically. To empty the water container do the following: Switch off the unit and remove the plug from the wall socket.
  • Page 15 C L E A N I N G  WA R N I N G ! First of all switch off the unit and pull the plug out of the wall socket. Clean the housing with a soft, damp cloth. Never use aggressive chemicals, petrol, d e t e rgents or other cleansing solutions.
  • Page 16: Troubleshooting

    TROUBLE SHOOTING Problem Cause Solution Connect to a functioning outlet No power supply. and switch on. Empty the internal water Is the LCD light flashing. container (refer to Chapter E). The unit does not function. De-activate Timer function (refer Timer function is active. to Chapter C).
  • Page 17: Technical Data

    Damage caused by not using suitable Zibro filters is not covered by the gua- rantee. To prevent unnecessary expense, we recommend that you always first care f u l l y consult the instructions for use.
  • Page 18 Holloway Bank, Wednesbury tel: +43 7434 44867 West Midlands WS10 OAW fax: +43 7434 44868 tel.: +44 121 506 1818 email: pvgaustria@zibro.com fax: +44 121 505 1744 email: gases@lister.co.uk e BELGIË > ITALIA PVG Belgium NV/SA Industrielaan 55 PVG Italy SRL 2900 SCHOTEN Via Niccolò...