(Example depicts a single arc grouping, and may be repeated for each arc in the system)
Ethernet
Work
Connect to optional
K2282-1 System Interface
for Synchronized
Multiple Arc Applications
K 179 5-XX C ables
S 12 (Input)
Connection Diagram - Parallel Machines
* Work Cables
E lectrode
Rea r view of machines
S13 (Output)
* Refer to "Output Cable Guidelines" for recommended cable size.
Front view o f machines
Common bus connections
recommended for
excessive cable length
applications. (Locate
close to power sources.)
Note:
Ethernet connectivity allows machines to share critical
parameter information. Proper configuration requires the use of
the Weld Manager and SubarcCellConfig software utilities.
Connect additional SLAVE
machines as required to reach
desired capacity.
Note: Each arc is limited to 5
SLAVE machines per MASTER
(6 machines total)
* Electrode
Cables
Ethernet S witch