Advertisement

F-14
TROUBLESHOOTING AND REPAIR
INPUT VOLTAGE
230 VAC
230 VAC
230 VAC
230 VAC
230 VAC
230 VAC
230 VAC
230 VAC
12. If ALL the voltages tested are incorrect
or missing, test for correct nameplate
input voltage between the H1 lead at the
ON/OFF POWER SWITCH to H2 or H3
at the reconnect panel. Voltage tested
will vary depending on input voltage con-
nection. See Wiring Diagram for test
point locations.
A. If the input voltage test is incorrect,
check for loose or broken leads between
the reconnect panel and the ON/OFF
POWER SWITCH.
B. Test the ON/OFF POWER SWITCH for
proper operation.
TABLE F.1. Test Points
TEST POINTS
X1-X2
X1-X3
X1-X4
X1-X5
X1-X6
X1-X7
X1-X8
X9-X10
13. If the correct nameplate voltage is being
applied to the main transformer and one
or more of the secondary voltages are
missing or are incorrect, the main trans-
former may be faulty. Replace.
14. When test is complete, replace tool tray,
case sides and top.
POWER MIG® 215
EXPECTED VOLTAGE READING
11.9-13.0 VAC
14.1-15.2 VAC
16.2-17.5 VAC
18.4-19.7 VAC
20.5-22.0 VAC
22.7-24.2 VAC
24.8-26.5 VAC
26.9-28.8 VAC
F-14

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power mig 215

Table of Contents