4-3. Trouble Codes List

Display
Codes
11
DC 160 V high voltage warning (over 192 V)
12
DC 160 V low voltage warning (below 128 V)
21
DC 60 V high voltage warning (over 75 V)
22
DC 60 V low voltage warning (below 45 V)
High temp. warning at panel top on power
31
supply block side (over 59 dC)
Shut down by high temp. at panel top on
39
power supply block side (over 68 dC)
High temp. warning at panel top on input
41
terminal block side (over 55 dC)
Shut down by high temp. at panel top on
49
input terminal block side (over 64 dC)
51
Power supply block intake fan 1 stop warning
52
Power supply block intake fan 2 stop warning
53
Panel top input terminal block exhaust fan stop warning
54
Panel top power supply block exhaust fan stop warning
55
Panel top center exhaust fan stop warning
58
Fan control circuit alarm warning
61
Power supply block high internal temp. warning
79
Shut down by faulty 5V for digital circuits
81
EEPROM1 Access error
82
EEPROM2 Access error
Shut down by panel trouble
(when digital 5 V is normal, DC 160 V is below 40 V, and
99
DC 60 V is below 20 V, the power supply is restarted 3 times
repeatedly, but these voltages are not recovered normally)
4-4
Function Trouble Status
Name
DC 160V
DC 160V
DC 60V
DC 60V
PANEL TEMP1
PANEL TEMP1
PANEL TEMP2
PANEL TEMP2
FAN STATUS
FAN STATUS
FAN STATUS
FAN STATUS
FAN STATUS
P/S TEMP