Gun Trigger And 1Cr Relay Contact Control Circuits - Lincoln Electric LN-8 SVM132-A Service Manual

Semiautomatic wire feeder
Table of Contents

Advertisement

E-3
FIGURE E.2 – GUN TRIGGER AND 1CR CONTACT CONTROL CIRCUITS
REMOTE
OUTPUT
CONTROL
#75
#76
#77
#32
INPUT
RECEPTACLE
#31
#2
&
#4
C
O
N
T
A
C
T
O
R
CONTROL
OPTIONAL
BURNBACK
BOARD
GUN TRIGGER AND 1CR
RELAY CONTACT
CONTROL CIRCUITS
When the gun trigger switch is activat-
ed (closed) the 1CR relay is energized.
Three sets of isolated contacts incor-
porated within the 1CR relay perform
several functions. One set of contacts
completes the circuit to energize the
wire feed motor armature and also the
auxiliary circuit #7 and #32A. Another
set of contacts control the motor field
circuit polarity which, along with the
wire feed switch, dictate the wire feed
direction. The third set of contacts
control the #2 and #4 contactor circuit
NOTE: Unshaded areas of block logic diagrams are the subject of discussion.
THEORY OF OPERATION
#21
VARIABLE VOLTAGE
BOARD
WIRE FEED
SPEED CONTROL
CIRCUIT
BREAKER
#32A
2 OHMS
#531
FUSE
REED
GLP
SWITCH
ELECTRODE
#567
METER
SHUNT
ARMATURE
CONTROL
BOARD
#3
2
A
FIELD
RELAY
BOARD
WIRE
TRIGGER
INTERLOCK
FEED
TRANS.
SWITCH
SWITCH
which enables the power source weld-
ing output. The #2 and #4 contactor
circuit is passed through the optional
burnback board which delays the
"opening" of the circuit and prevents
the electrode from "sticking" in the
weld puddle.
The interlock switch, reed switch,
ground lead protector (GLP), and ther-
mal circuit breaker are all incorporated
in the gun trigger circuit. In case of a
fault condition, the GLP or thermal cir-
cuit breaker will disable the trigger cir-
cuit. The interlock switch and reed
switch enhance the gun trigger circuitry
by allowing the operator to release the
trigger button and continue welding.
LN-8
WIRE
THERMAL
FEED
CIRCUIT
MOTOR
BREAKER
GUN
CABLE
RECEPTACLE