INNERSHIELD (FCAW)
CONVERSION
Several changes are needed to convert the unit for
operation with the Innershield (FCAW) process. The
Innershield Kits include all the necessary accessories
for this conversion and are provided for this purpose.
The following conversions should be made using the
contents of a kit:
1. Change the output polarity to DC(-). See "Work
Cable Installation" section for details.
2. Install proper drive roll for the wire size selected.
See "Changing Drive Roll" in Maintenance section
for details.
3. Install the proper gun liner and tip for the wire size
selected. See "Component Replacement" in
Maintenance section for details.
4. Remove gas nozzle (if installed) and install gasless
nozzle. To remove, simply unscrew.

REPLACEMENT PARTS

Complete Gun and Cable Assembly
L8311-6
Contact Tip .025" (0.6 mm)
S19726-1
Contact Tip .030" (0.8 mm)
S19726-2
Contact Tip .035" (0.9 mm)
S19726-3
Contact Tip .045" (1.2 mm)
S19726-4
Contact Tip-Tapered .025" (0.6 mm)
S20278-1
Contact Tip-Tapered .030" (0.8 mm)
S20278-2
Contact Tip-Tapered .035" (0.9 mm)
S20278-3
Contact Tip-Tapered .045" (1.2mm)
S20278-4
ACCESSORIES
Contact Tip .035A" (0.9 mm)
S24221-1 (Aluminum Tip)
Liner .023 - .030" (0.6 - 0.8 mm)
M16291-2
Liner .030 - .035" (0.8 - 0.9 mm)
M16291-5
Liner .035/.045" (0.9/1.2 mm)
M16291-1
Liner - Nylon .035/.045" (0.9/1.2 mm)
M18971-1 (Aluminum Feed)
Gas Diffuser
S19728
Gas Nozzle
M16294
Gas Nozzle-Tip Recessed 3/8" (9.5 mm)
Opening I.D.
M16684
Gas Nozzle-Tip Recessed 1/2" (12.7 mm)
Opening I.D.
M16684-1
Gas Nozzle-Tip Recessed 5/8" (15.9 mm)
Opening I.D.
M16684-2
Spot Welding Nozzle
M17846-1
Gasless Nozzle (Innershield Only)
M16418