C-2
INNERSHIELD (FCAW)
CONVERSION
Several changes are needed to convert the unit for
operation with the Innershield (FCAW) process:
1. Change the output polarity to DC(–). See "Work
Cable Installation" in Installation section for details.
2. Install proper drive roll for the wire size selected.
See "Changing Drive Roll" in Maintenance section
for details.
3. Install the proper gun liner
selected. See "Component Replacement" in
Maintenance section for details.
4. Remove gas nozzle (if installed) and install the
gasless nozzle. To remove, simply unscrew.
5. Load wire into machine and thread into gun and
cable per "Welding Wire Loading" section.
1
The factory installed gun liner will feed up to .035
(0.9mm) wire.
ACCESSORIES
1
and tip for the wire size
Pro-MIG 135

REPLACEMENT PARTS

Complete Gun and Cable Assembly
L8311-6 (K530-4)
Contact Tip .025" (0.6 mm)
S19726-1
Contact Tip .030" (0.8 mm)
S19726-2
Contact Tip .035" (0.9 mm)
S19726-3
Contact Tip-Tapered .025" (0.6 mm)
S20278-1
Contact Tip-Tapered .030" (0.8 mm)
S20278-2
Contact Tip-Tapered .035" (0.9 mm)
S20278-3
Liner .023 - .030" (0.6 - 0.8 mm)
M16291-2
Liner .030 - .035" (0.8 - 0.9 mm)
M16291-6
Liner .035/.045" (0.9/1.2 mm)
M16291-1
Gas Diffuser
S19728
Gas Nozzle
M16294
Gas Nozzle-Tip Recessed 3/8" (9.5 mm)
Opening I.D.
M16684
Gas Nozzle-Tip Recessed 1/2" (12.7 mm)
Opening I.D.
M16684-1
Gas Nozzle-Tip Recessed 5/8" (15.9 mm)
Opening I.D.
M16684-2
Spot Welding Nozzle
M17846
Gasless Nozzle (Innershield Only)
M16418