Lincoln Electric IDEALARC R3R 600-I Operator's Manual page 23

Lincoln electric welder user manual
Hide thumbs Also See for IDEALARC R3R 600-I:
Table of Contents

Advertisement

E-10
2. POWER DIODE TEST
a. Establish the polarity of the ohmmeter leads
and set to X10 scale.
b. Connect the ohmmeter positive lead to anode
and negative lead to the cathode.
c. Reverse the leads of the ohmmeter from Step
b.
d. A shorted diode will indicate zero or an equal-
ly low resistance in both directions. An open
diode will have an infinite or high resistance in
both directions, and a good diode will have a
low resistance in Step b and a much higher
resistance in Step c.
TROUBLESHOOTING
DIAGRAM 1
DIAGRAM 2
K. POWER SILICON CONTROLLED REC-
TIFIER TEST
The SCR must be mounted in the heat sink when
making this test.
a. Connect the ohmmeter (set to the X10 scale)
b. Reverse the leads of the ohmmeter from Step a.
c. A shorted SCR will indicate zero or an equally
d. Establish the polarity of the ohmmeter. Connect
e. An open gate circuit will have an infinite or high
IDEALARC R3R 600-I
leads to the anode and cathode.
low resistance in one or both directions.
the positive lead to the gate and the negative
lead to the cathode.
resistance. A good gate circuit will read a low
resistance, but not zero ohms.
E-10