3.4 Hang the unit on the wall mounting bracket ensuring the location
bolt locates in the hole in the wall bracket. Position the moulded
spacer block between the tab on the bottom cover moulding and the
wall. Insert a No. 10 x 2 1/2"long screw through the tab and spacer
block and tighten into wall plug.
4.0 INSTALLATION - OPEN OUTLET
4.1 When installed as an Open Outlet water heater the outlet acts as
a vent and must not be connected to any form of tap or fitting
not recommended by Heatrae Sadia.
4.2 Only one outlet can be served. The fittings supplied include an Inlet
Tap, 300mm Open Outlet Spout, a 15mm x 1/2" straight Push Fit
connector and a 15mm Push Fit cap. The heater should be sited so
that the spout can discharge into a suitable sink or basin.
4.3 Streamline option packs J, K, M, P, Q, R or S can be used in place
of the spout to provide a single tap outlet. Flow rates will be at a
reduced rate. Note: item 4.7
4.4 The cold water supply may be taken from the cold water mains or
from a cold water feed cistern complying with Water Byelaw 30
with a minimum recommended pressure of 0.4 bar (4 metres head).
A drain cock should be incorporated in the supply to facilitate
draining the heater for maintenance.
4.5 The inlet tap should be fitted to the INLET pipe of the heater. The
inlet must not be connected directly to the cold water mains
supply. The Outlet Spout should be fitted to the OUTLET pipe
using the 15mm x 1/2" straight push fit connector supplied in the
fittings kit.