BV4536, BV5142 Natural Vent Gas Fireplace
LIGHTING INSTRUCTIONS MILLIVOLT
1. STOP! Read the safety information before pro-
ceeding.
2. Open access door on left side of floor to reveal gas
valve. Locate RS-OFF-ON rocker switch on left
side inner chamber.
3. Turn RS-OFF-ON rocker switch to "OFF". Turn re-
mote switch to "OFF".
4. Push in gas valve knob and turn clockwise
"OFF".
5. Wait five (5) minutes to clear out any gas. Smell
for gas, including near the floor. If you smell gas,
STOP! Follow B in the safety information. If you
don't smell gas, go to the next step.
6. Find the pilot located under the log.
7. Turn the gas valve counterclockwise
lot".
1. Turn RS-OFF-ON rocker switch to "OFF".
2. Turn off all electric power to the appliance if service is to be performed.
3. Close lower door.
26
8. With the control knob pushed in, push in and re-
9. Continue pushing the control knob in for a further
10. • If the pilot will not stay lit after several tries, turn
to
11. Turn knob counterclockwise
12. After the pilot has been lit for one minute, the burn-
to "Pi-
TO TURN OFF GAS
OPERATING INSTRUCTIONS
lease the piezo ignitor button to light the pilot.
60 seconds to prevent the flame detector from
shutting off the gas while the probe is warming up.
Release the control knob.
the gas control knob clockwise
call a service technician or gas supplier.
• If the knob does not pop out when released, stop
and call a service technician or gas supplier.
er can be turned on. Turn RS-OFF-ON switch to
"ON" or turn RS-OFF-ON switch to "RS" and re-
mote switch to "ON".