Convenience Operation - Panasonic CU-V7CKP5 Service Manual

Room air conditioner
Hide thumbs Also See for CU-V7CKP5:
Table of Contents

Advertisement

CS-V7CKP CU-V7CKP5 / CS-V9CKP CU-V9CKP5 / CS-V12CKP CU-V12CKP5
I Setting the Fan Speed
• Press 4 to select:-
FAN
FAN
FAN
AUTO
FAN
Automatic Fan Speed
The speed of the indoor fan is adjusted
automatically according to the operation.
The indoor fan stops occasionally during
cooling operation.
I Setting the Vertical Airflow Direction
• Press 5 or 6 to select:-
COOL / DRY Operation
AUTO
36°
Swing up/down
Automatically
MANUAL
Five stages of adjustment
can be made between
14° ~ 36°.
Heat Pump Model
COOL / DRY Operation
AUTO
36°
Swing up/down
Automatically
MANUAL
Five stages of adjustment
can be made between
14° ~ 36°.
AUTOHEAT
8
MODE
7
AUTO
1
5
OFF
CHECK
SETTING THE TIMER
Ensure that the current time is correct before setting the
timer. The timer cannot be set if the time display is
flashing.
I ON-TIMER Operation
To start the air conditioner operation automatically.
• Press 1 to set the operation.
• Press 2 to increase or decrease the time.
• Then press 3.
• To cancel this operation, press 4.
I OFF-TIMER Operation
To stop the air conditioner operation automatically.
• Press 5 to set the operation.
• Press 2 to increase or decrease the time.
• Then press 3.
• To cancel this operation, press 4.
G Timer Mode Operation Details
• When the ON-Timer is set, operation will start
before the actual set time. This is to enable the
room temperature reaches the set temperature at
the set time.
Cooling Model
COOL,DRY, –>15 minutes
AUTO
in advance
• Once the ON/OFF Timer is set, operation will start/
stop at the set time everyday.
• The current time is not displayed when the timers
are set.
• When both timers are used together, the TIMER
mode indicator on the indoor unit remains lit even
when the operation is stopped by the OFF-TIMER.
I Setting the Horizontal Airflow Direction
– Low Fan Speed
– Medium Fan Speed
– High Fan Speed
G Use this air conditioner under the following
conditions:
Cooling Model
FAN Operation
AUTO
61°
Move up/down
Automatically
MANUAL
Five stages of adjustment
can be made between
0° ~ 61°.
HEAT Operation
AUTO
– When the discharge air
temperature is low such
as at the start of heating
G Notes
operation, the air blows
at horizontal level. As
If the unit is not going to be used for an extended
the temperature rises,
period of time, turn off the main power supply. If it is
the hot air blows at a
left at the ON position, approximately 2.5 W of
downward direction.
electricity will be used even if the indoor unit has been
– To stop this operation,
turned off with the remote control.
press MANUAL.
If operation is stopped, then restart immediately, the
MANUAL
unit will resume operation only after 3 minutes.
Five stages of adjustment
can be made between
0° ~ 61°.
COOL
DRY FAN
AUTO
AUTO
FAN

CONVENIENCE OPERATION

OFF/ON
I Powerful Mode Operation
To obtain the set temperature quickly.
• Press 6.
QUIET
POWERFUL
6
* Powerful mode indicator (orange) on the indoor
AIR SWING
MANUAL
FAN SPEED
* Powerful mode will operate for 15 minutes only.
1
2
3
3
• To cancel this operation, press once more.
ON
SET
4
G Powerful Mode Operation Details
CANCEL
2
TIMER
• The changes of the temperature and airflow volume
RESET CLOCK
• The remote control display remains unchanged.
• If operation mode button is pressed, powerful
• During FAN – Air circulation operation, the powerful
Powerful Mode
COOL / DRY
(for Heat Pump
Heat Pump Model
COOL,DRY, –>15 minutes
in advance
HEAT, AUTO –>30 minutes
in advance
• Adjust it manually
Cooling Model
Unit in °C
Indoor
Outdoor
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
DBT
WBT
DBT
WBT
Maximum Temperature
32
23
26
43
Minimum Temperature
16
11
11
16
Heat Pump Model
Unit in °C
Indoor
Outdoor
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
DBT
WBT
DBT
WBT
Maximum Temperature-Cooling
32
23
43
26
(Maximum Temperature-Heating)
(30)
(-)
(24)
(18)
Minimum Temperature-Cooling
16
11
16
11
(Minimum Temperature-Heating)
(16)
(-)
(-5)
(-6)
unit will light up.
are automatic.
operation will be cancelled.
operation are not available.
(cooling model only)
Temperature
Airflow
Operation
volume
3°C lower
than set temp.
Super High
HEAT
3°C higher
than set temp.
Automatic
model only)
32
G Operation Details
COOL – Cooling Operation
To set the room temperature at your preference
cooling comfort.
AUTO – Automatic Operation
Sense indoor temperature to select the optimum
mode.
Temperature is not displayed on the remote control
during AUTO operation.
DRY – Soft Dry Operation
A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.
During Soft Dry operation, the indoor fan operates at
Low fan speed.
HEAT – Heating Operation
(for Heat Pump Model only)
Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
falls, the heating capacity of the unit might be
reduced.
Defrosting Operation
Depend on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor
unit.
FAN – Air Circulation Operation
(for Cooling Model only)
When the room temperature reaches the set
temperature, operation commences at Low airflow
volume. It stops when the room temperature drops to
2°C below the set temperature.
(It is useful when using a heater).
I Quiet Mode Operation
To provide quiet operation.
• Press 7.
* Quiet mode indicator on the indoor unit will light
up.
• To cancel this operation, press once more.
G Operation Details
• Air flow sound will reduce during operation.
I Ionizer Mode Operation
Produce negative ion for fresh air.
• Press 8.
* Ion mode indicator on the indoor unit will light up.
• To cancel this operation, press once more.
G Operation Details
• Air conditioner ON:
Provide negative ion during operation.
• Air conditioner OFF:
Provide negative ion with FAN operation.
• If blinking, press 8 twice.
If still blinking, please call service.