Lincoln Electric BULLDOG SVM208-A Service Manual page 57

Lincoln electric portable generator user manual
Table of Contents

Advertisement

F-9
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
Engine will not start.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
TROUBLESHOOTING AND REPAIR
POSSIBLE AREAS OF
MISADJUSTMENT(S)
ENGINE PROBLEMS
1. Make sure the ON/OFF switch is
in the "ON" position.
2. Check spark plug boot and wire
for loose or faulty connection.
3. Make sure that the fuel shutoff
valve is in the "ON" position.
4. Make certain that the engine has
adequate fuel and oil.
5. Adjust the choke to prevent car-
buretor flooding.
6. The recoil starter may not be
engaged with the engine. gently
hit the blower housing and/or pull
the rope to its fully extended
position and rapidly wiggle it.
Repeat until the clutch engages
with the engine shaft and resis-
tance is felt.
7. Low oil and engine low oil shut-
down protection will not allow
unit to start. Light in ON-OFF
switch will flash when engine is
cranked.
with low oil shutdown protection
only).
CAUTION
BULLDOG® 140
1. Check the fuel line for breaks or
2. The spark plug may be faulty.
3. Service the engine as outlined
4. The engine magneto may be
5. The engine may be faulty.
(Engines equipped
RECOMMENDED
COURSE OF ACTION
obstructions. Replace the fuel
filter. DO NOT RUN THE EN-
GINE WITHOUT AN IN-LINE
FUEL FILTER.
Replace.
in the Maintenance Section of
this manual.
faulty.
Consult
Briggs
Stratton owner's manual.
Replace.
F-9
&

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bulldog 140