Initializing The B, E, F; Modification Of B, E, F - Sony DSC-S70 Service Manual

Hide thumbs Also See for DSC-S70:
Table of Contents

Advertisement

1-2-2. Initializing the B, E, F, 7 Page Data
1. Initializing the B, E, F, 7 Page Data
Note: If the B, E, F Page data has been initialized, "Modification
of B, E, F, 7 Page Data" and following adjustments need
to be performed again.
1) Modification of B, E, F, 7 page data
2) Video system adjustments
3) Camera system adjustments
Adjusting page
Adjusting Address
Adjusting page
Adjusting Address
Adjusting page
Adjusting Address
Adjusting page
Adjusting Address
Initializing Method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 6, address: 00, and set data: 2D.
3)
Select page: 6, address: 01, set data: 2D, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 6, address: 02, and check that the data changes to
"01".
5)
Perform "Modification of B, E, F, 7 Page Data".
2. Modification of B, E, F, 7 Page Data
If the B, E, F, 7 Page data has been initialized, change the data of
the "Fixed data-2" address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the
camcorder may not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of B, E, F, 7 Page data
1)
Select page: 2, address: 00, and set data: 29.
2)
Select page: 2, address: 01, and set data: 29, and press the
PAUSE button of the adjustment remote commander.
F
10 to FF
E
00 to FF
B
00 to FF
7
00 to AF
3. B Page table
Note 1: Fixed data-1: Initialized data.
(Refer to "1. Initializing the B, E, F, 7 Page Data")
Note 2: Fixed data-2: Modified data.
(Refer to "2. Modified of B, E, F, 7 Page Data")
Address
Initial value
00
01 to FF
4. E Page table
Note 1: Fixed data-1: Initialized data.
(Refer to "1. Initializing the B, E, F, 7 Page Data")
Note 2: Fixed data-2: Modified data.
(Refer to "2. Modified of B, E, F, 7 Page Data")
Address
Initial value
00 to FF
5-9
Remark
Fixed data-2
Fixed data-1 (Initialized data)
Remark
Fixed data-1 (Initialized data)

Advertisement

Table of Contents
loading

Table of Contents