High Heat Airflow - Carrier 59TP6A Product Data

Performance two---stage, variable speed 4---way multipoise condensing gas furnace series 1
Table of Contents

Advertisement

Cooling Switch Settings
Unit Size
SW2-8
SW2-7
100- - 20
Clg Default:
OFF
OFF
OFF
OFF
OFF
OFF
Cooling (SW2)
ON
OFF
ON
OFF
ON
ON
Clg SW2:
Maximum Clg Airflow

High Heat Airflow

Heating
(SW1)
Low Heat Airflow
120- - 22
Clg Default:
OFF
OFF
OFF
OFF
OFF
OFF
Cooling (SW2)
ON
OFF
ON
OFF
ON
ON
Clg SW2:
Maximum Clg Airflow
High Heat Airflow
Heating
(SW1)
Low Heat Airflow
1. Nominal 350 CFM/ton cooling airflow is delivered with SW1 ---5 and SW2 ---2 set to OFF.
Set both SW1 ---5 and SW2 ---2 to ON for +7% airflow (nominal 370 CFM/ton).
Set SW1 ---5 to ON and SW2 ---2 to OFF for +15% airflow (nominal 400 CFM/ton).
Set SW2 ---2 to ON and SW1 ---5 to OFF for ---7% airflow (nominal 325 CFM/ton).
The above adjustments in airflow are subject to motor horsepower range/capacity.
2. Maximum cooling airflow is achieved when switches SW2 ---6, SW2 ---7, SW2 ---8 and SW1 ---5 are set to ON, and SW2 ---2 is set to OFF.
3. All heating CFM's are when low heat rise adjustment switch (SW1 ---3) and comfort/efficiency adjustment switch (SW1 ---4) are both set to OFF.
4. Ductwork must be sized for high ---heating CFM within the operational range of ESP . Operation within the blank areas of the chart is not recommended
because high ---heat operation will be above 1.0 ESP .
5. All airflows of 1880 CFM or less on 21" and 24.5" casing size furnaces are 5% less on side return only installations.
6. Return air above 1800 CFM on 24.5" casing requires two sides, one side and bottom, or bottom only to allow sufficient airflow to the furnace.
7. For upflow applications, air entering from one side into both the side of the furnace and a return air base counts as a side and bottom return.
8. Airflow not stable at this ESP .
AIR DELIVERY - - CFM (CONTINUED)
SW2-6
0.1
OFF
1890
ON
1015
ON
OFF
1080
ON
ON
1155
OFF
1310
ON
1520
ON
OFF
1890
ON
ON
2290
2
2290
3
1905
3
1480
OFF
2010
ON
1015
ON
OFF
1075
ON
ON
1205
OFF
1400
ON
1615
ON
OFF
2010
ON
ON
note 8
2
note 8
3
note 8
3
1735
External Static Pressure (ESP)
0.2
0.3
0.4
0.5
1845
1800
1755
1700
825
630
485
405
895
815
740
690
1080
1020
940
890
1260
1195
1140
1075
1475
1425
1365
1315
1845
1800
1755
1700
2230
2160
2085
2005
2230
2160
2085
2005
1865
1825
1775
1730
1435
1375
1330
1265
1960
1910
1850
1800
805
645
550
480
975
915
835
765
1135
1055
1000
935
1330
1260
1190
1145
1550
1500
1435
1370
1960
1910
1850
1800
2375
2300
2205
2115
2375
2300
2205
2115
2375
2300
2205
2115
1675
1625
1560
1500
8
0.6
0.7
0.8
0.9
1655
1610
1560
1510
325
See note 4
615
555
475
See note 4
825
785
710
660
1025
970
925
875
1255
1210
1155
1110
1655
1610
1560
1510
1915
1820
1730
1640
1915
1820
1730
1640
1685
1640
1590
1545
1215
1160
1115
1060
1750
1690
1645
1565
See note 4
See note 4
See note 4
1080
1035
970
905
1325
1265
1215
1160
1750
1690
1645
1565
2010
1890
1750
1645
2010
1890
1750
1645
2010
1890
1750
1645
1455
1395
1345
1285
1.0
1460
590
810
1055
1460
1525
1525
1490
1005
1480
845
1110
1480
1550
1550
1550
1225