Page 1
XOV30S XOV36S XOV42S NEED HELP? Call our ventilation experts toll free al 800-966-8300 AVEZ-VOUS BESOIN D’AIDE ? Contactez nos experts au numéro gratuit 800-966-8300 ¿NECESITA AYUDA? Póngase en contacto con nuestros expertos a través del número gratis 800-966-8300 RANGE HOOD - User instructions HOTTE DE CUISINE - Notice d’utilisation...
Page 2
The warranty is extended to the original purchaser for products purchased for ordinary home use in North America. Should you require service for your XO product call a product service specialist at 800.966.8300 What is not covered Improper Installation.
Page 3
ENGLISH IMPORTANT SAFETY INSTRUCTIONS FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORTANT: Save these Instructions for the Local Electrical Inspectors use. INSTALLER: Please leave these Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference.
Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambè). C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter. D. Use proper pan size. Always use cookware appropriate for the size of the surface element. E. Keep fan, filters and grease laden surface clean. F.
Page 5
D. Ducted fans must always be vented to the outdoors. E. This unit must be grounded. WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. WARNING - UNDER CERTAIN CIRCUMSTANCES DOMESTIC APPLIANCES MAY BE DAN- GEROUS. A. Do not check filters with hood working. B.
DUCT FITTINGS: Equivalent Total Duct Quantity This Hood Must Use an Dimensions: Number Equivalent Piece: Used: Length*: Length: 6" Round Duct. It Can Transition to 3-1/4" x 1 ft. (per foot Round, straight 10" or 3-1/4" x 12" Duct. lenhgth) 3-1/4"...
WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
Page 8
PRODUCT DIMENSIONS AND CLEARANCE XOV30S - XOV36S - XOV42S: › Front of hood › Side of hood �������� �������� › Top of hood › Mounting height and clearance: ����������������� ��������������� ��� - 8 -...
Page 9
INSTALLATION INSTRUCTIONS INSTALLATION - VENTED TO THE OUTSIDE 1. MOUNT TO THE WALL: Drill the holes A respecting the distances indicated (Fig.1). Fix the appliance to the wall and align it in horizontal position to the wall units. When the appliance has been adjusted, definitely fix the hood using the screws A (Fig.2).
POWER SUPPLY: IMPORTANT – (Please read carefully) WARNING: FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED. Remove house fuse or open circuit breaker before beginning installation. Do not use an extension cord or adapter plug with this appliance. Follow National electrical codes or prevailing local codes and ordinances.
2. CONNECT ELECTRICAL: WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PER- SONS, OBSERVE THE FOLLOWING: Before making electrical connections to power supply, the electrical box must be secured in place as indicated in Fig.3. Before installing the appliance fix the electrical box as indicated in Fig.3.
Page 12
• Power Supply Connection: For connection to the power supply refer to the following Fig.4-5: 1. Remove the power supply cover by undoing the (2) screws Fig.4-5A. 2. Break through the hole on the box cover. 3. Secure the power supply conduit to the cover. 4.
Page 13
- Carry out the power supplly connection in accordance with the national electric code, ANSI/NFPA 70-1999. 5. Insert the wires into the box, then close the box cover, securing it using the screws that were previously removed. The appliance must be installed at a mini- mum height of 27"...
Page 14
4. INSTALL THE DUCT COVER: Arrange the electrical power supply within the dimensions of the decorative flue. If your appliance is to be installed in the ducting version or in the version with external motor, prepare the air exhaust opening. Adjust the width of the support bracket of the upper flue (Fig.8).
Page 15
DUCTLESS RECIRCULATING OPTION: ��� � � � � ��� CARBON FILTER KIT XORFK02 (30"): We have an air diverter A, 10 screws B, 2 rectangular filters C and the bracket D. ��� ��� � � � � ��� ��� CARBON FILTER KIT XORFK03 (36" - 42"): We have an air diverter A, 12 screws B, 4 rectangular filters C and the bracket D.
Page 16
� � � � � � ���� ��� ��� ��� ��� ��� ��� Fig.1: Remove the 2 screws E and have the top flue F go Fig.2: Make a mark on the into the bottom flue G. Remove the two flues F/G and wall and then drill a hole 1/4"...
Page 17
6" ROUND FLEXIBLE METAL DUCT PIPE INCLUDED ��� ��� ��� ��� ��� ��� Fig.5: Fasten the air diverter Fig.6: Once the air diverter has been inserted permanently to the wall with a into the bracket and fastened to the wall connect screw (the hole previously drilled the flexible (6"...
Page 18
��� � � � � � � � � Fig.9: Take the bracket D and fasten it to the hood using the 10 screws B (provided). Take the 2 rectangular filters C and apply them onto the bracket D as shown in the figure. ���...
Page 19
� � ��� ��� ��� Fig.11: Put the aluminum panels back in place (Fig.8). - 19 -...
MAINTENANCE • We recommend that the cooker hood is switched on before any food is cooked. We also recommend that the appliance is left running for 15 minutes after the food is cooked, in order to thoroughly eliminate all contaminated air. The ef- fective performance of the cooker hood depends on constant maintenance;...
Page 21
- DO NOT allow deposit to remain for long periods of time. - DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface causing rust. - DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel for extended periods.
Page 22
FUSE • The halogen lamps circuit is controlled by a fuse 5x20 mm, 125V 5A. In case of necessity it can be replaced only by spe- cialized personnel. • Replacing halogen light bulbs: In order to replace the dichroic lamps, carefully remove the lamp from the lamp holder with the help of a small flat screw- driver or a similar tool.
INSTALLATION PREPARATION: Check installation hardware: Locate the hardware package packed with the hood and check contents. TYPE DESCRIPTION N° 1/8" x 1/2" Screws for attaching the decorative flue to the mounting bracket. 2-piece decorative duct cover Duct bracket Aluminum filter (dimension shown for reference only) ��������...
Page 27
XOV Spec Sheet Model: XOV30S - XOV36S - XOV42S Sizes: 30"- 36"- 42" Depth: 24" Features and Benefits: - Premium 700 CFM (EBM) high velocity, whisper quiet blower optimally removes Smoke, Grease and Odors. - Illuminated Touch controls with 3 level light dimmer.