  • Page 1 Version 1.0...
  • Page 3: Table Of Contents

    4.2 Connection to the mains 4.3 DMX-512 connection/connection between fixtures 4.4 Fitting the frost filtr 5. ArcWash 136 RGB - DMX protocol,version 1.0 6. ArcWash 136 RGB - Control menu map 7. Functions of the control panel 7.1 Fixture Address 7.2 Fixture informations...
  • Page 4: Safety Instructions

    CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing! FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOU INITIAL START - UP! 1. Safety instructions Every person involved with installation and maintenance of this device have to: - be qualified - follow the instructions of this manual CAUTION!
  • Page 5: Description Of The Device

    transport handles. When choosing the installation-spot, please make sure that the device is not exposed to extreme heat, moisture or dust. There should not be any cables lying around. You endanger your own and the safety of others! The minimum distance between light-output and the illuminated surface must be more than 0.8 meter. Make sure that the area below the installation place is blocked when rigging, derigging or servicing the fixture.
  • Page 6: Installation

    4. Installation 4.1 Mounting the fixture Warning ! Use 2 clamps to mount the fixture on the truss. Follow the instructions mentioned at the bottom of the base. Make sure that the device is fixed properly! Ensure that the structure (truss) to which you are attaching the fixtures is secure.
  • Page 7: Connection To The Mains

    4.2 Connection to the mains Connect the fixture to the mains with the power cord. If the plug on the flexible cord is not the right type for your socket outlets,do not use an adaptor,but remove the plug from the cord and discard.Carefully prepare the end of the the supply cord and fit a suitable plug. The earth has to be connected! The occupation of the connection-cables is as follows: Cable (EU) Cable (US)
  • Page 8: Fitting The Frost Filtr

    4.4 Fitting the frost filtr The ArcWash 136 RG is supplied with clear front glass (factory fitted) and two types of frost filters (films). If you wish to use a diffusive light ,follow the steps to install desired frost filter: 2.Put the frost film on the front glass and centre the holes...
  • Page 9: Arcwash 136 Rgb - Dmx Protocol,Version

    5. ArcWash 136 RGB - DMX protocol,version 1.0 Mode 1 Mode 2 Type Value Function Channel Channel of control 0 - 255 proportional Pan movement by 530° Pan Fine 0 - 255 proportional Fine control of pan movement Tilt 0 - 255 proportional Tilt movement by 280°...
  • Page 10 Mode 1 Mode 2 Value Function Type of control Channel Channel 136-143 Macro 17 step 142-151 Macro 18 step 152-159 Macro 19 step 160-167 Macro 20 step 168-175 Macro 21 step 176-183 Macro 22 step 184-191 Macro 23 step 192-199 Macro 24 step 200-207...
  • Page 11: Arcwash 136 Rgb - Control Menu Map

    6. ArcWash 136 RGB - Control menu map Default settings=Bold print A001 (001-498) InFo tEMP. VErS. IC1.b. IC2.b. PErS. r.PAn (On,Off) r.tilt (On,Off) MI.SE (1...10...20) dM.Pr. (Mod.1,Mod 2) FEEd. (On,Off) P.t.Mo. (SP.Mo.,ti.Mo.) bL.Co.(On,Off) bl.P.t. (On,Off) BALA. (On,Off) C.bAL. rEd.b. (0..200..255) GrE.b.
  • Page 12: Functions Of The Control Panel

    This situation can occur if: - the 3 PIN XLR plug (cable with DMX signal from controller) is not connected with the input of the ArcWash 136 RGB. - the controller is switched off or defective, the cable or connector is defective or the signal wires are swap in the input connector.
  • Page 13: Manual Mode

    3.Repeat step 2 for green channel "GrE.b." and for blue channel "bLu.b". i.bLi. --- Initial blink.If this function is on,ArcWash 136 RGB makes auto-calibration (All LEDs light on 100% for a short time) after switching the fixture on.If this function is set off,you have to set manually every colour on max.brightness after switching on the driver before starting regular operating.This action should last min.
  • Page 14: Test Sequences

    7.5 Test sequences Use this menu to to run a demo-test sequences without an external controller, which will show you some possibilities of using ArcWash 136 RGB. 7.6 Stand-alone setting The fixtures on a data link are not connected to the controller but can execute pre-set programs which can be different for every fixture.
  • Page 15: Reset Function

    SLA. --- Slave.Select this menu if you want to set the the fixture as a slave. 7.6 Reset function This option enables the ArcWash 136 RGB to index all effects and return them to their standard positions. 7.7 Special functions Use this menu for special services like software update.
  • Page 16: Power Down Mode

    3.It is recommended that you exit all programs before running the Software Uploader. 4.Start the Software Uploader program. Select desired COM and then click Connect button. If the conection is OK, click Start Uploading button to start uploading. It will take several minutes to perform software update.
  • Page 17: Technical Specifications

    10. Technical specifications Power supply - Input Voltage:100-240V AC, 50/60 Hz - Fuse:T 2 A - Max.Pover Consumption:100 VA Optical system - 36 RGB LEDs - Standard 6° beam angle lenses - Optional 25° beam angle lenses Beampath Beam angle 6° 5 Distance (m) 0.05 0.16...
  • Page 18: Maintenance And Cleaning

    Data input/output - 3-pin XLR male socket for DMX data input - 3-pin XLR female socket for DMX data output Temperatures - Maximum ambient temperature: 40° C - Maximum housing temperature: 55° C Minimum distances - Min. distance from flammable surfaces: 0.5 m - Min.