Grounding Instructions - Comfort Glow CF26PRA Owner's Operation And Installation Manual

Unvented (vent-free) bay front gas log fireplace
Table of Contents

Advertisement

INSTALLATION
Continued
For Built-In Installation
WARNING: A licensed elec-
trician must connect the wiring
harness to electrical supply
following all local codes. Electri-
cian must provide a clamp on the
box cover to secure the wiring.
Wiring should be routed through
the bushing in the hole on the
outer casing of heater.
WARNING: ELECTRICAL

GROUNDING INSTRUCTIONS

This appliance is equipped with a
three-prong (grounding) plug for
your protection against shock
hazard and should be plugged
directly into a properly grounded
three-prong receptacle.
Blower Bracket
Assembly
Screw
Switch
Switch
Plate
Blower
Control
Shield
14
Strain
Relief
Power
Cord
Blue
Red
Clamp
Connector (not
included)
Figure 17 - Installing Blower Bracket Assembly
www.desatech.com
1. Install a snap bushing found in hardware kit
into one of the holes found on rear of blower
control shield. The other hole is for a strain
relief clamp (not supplied) to secure incoming
electrical supply.
2. Follow steps 2 through 6 in Installing Blower
Assembly, page 12. Also remove black wire
from middle/OFF switch terminal.
3. Remove black plastic strain relief and power
cord from switch plate (see Figure 17). The
power cord supplied will not be used in built-
in installations. Pop in the plastic snap bushing
found in hardware kit into the hole left by
supply cord/strain relief.
4. A licensed electrician must follow the wiring
diagram in Figure 18, page 15 to connect
incoming electrical supply to fan kit wiring
harness.
5. Test to make sure the blower is working
properly.
6. Reinstall hood assembly (see page 12) and
close lower louver door.
7. Place log set back into unit.
Wire
Harness
Outlet
Receptacle
Shield
Cover
Wire
Harness
113897-01E

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cf26nra

Table of Contents