Comfort Glow CF26PRA Owner's Operation And Installation Manual page 12

Unvented (vent-free) bay front gas log fireplace
Table of Contents

Advertisement

INSTALLATION
Continued
3. Assemble trim kit. See Assembling Trim,
page 11.
4. Place trim on the shoulder screws located on
the side and top of the fireplace. Firmly snap
the trim over the shoulder screws on fireplace
(see Figure 13).
5. Place mantel base close to wall in desired
fireplace location.
6. Install gas line. See Connecting To Gas Sup-
ply, page 15
7. Carefully place fireplace on mantel base and
center left to right. Check for gas leaks. See
Checking Gas Connections, page 17.
8. Refer to instructions provided with the mantel
for permanent attachment to wall.
9. Slide mantel around fireplace. Be careful not
to damage wall or mantel.
10. Adjust assembly to remove any gaps. From
back side of fireplace, attach two 2" wood
screws through base mounting blocks at-
tached to bottom sides of mantel into base
(see instructions provided with mantel).
11. Attach remaining two 3" wood screws from
hardware pack through openings inside of
fireplace sides into the mantel. See Figure 12
for screw hole location.
Figure 12 - Removing Hood
Assembled
Trim
Figure 13 - Attaching Trim to Fireplace
1
INSTALLING BLOWER ASSEMBLY
GA3450TA
prior to disconnection when
servicing controls. Wiring errors
can cause improper and danger-
ous operation.
eration after servicing.
Note: If you are using a mantel with your heater,
use the following instructions. If your heater is
built-in, see For Built-In Installation on page 14.
1. Screen and hood should be removed from
fireplace (see page 11). Remove log set and
set aside.
2. Install snap bushings found in hardware kit
into both holes in rear of blower control shield
(see Figure 14).
3. Make sure the wire harness is firmly con-
nected to the terminals on the blower bracket
assembly.
4. Note the wire locations on back of AUTO/
OFF/ON switch. Carefully remove red wire
from the AUTO terminal and blue wire from
the ON terminal. Black wire can remain on
the middle or OFF terminal (see Figure 15,
page 13).
5. Carefully disconnect green and white wires
Mantel
from power cord harness at their insulated
Screw
connectors.
Location
6. In top of the heater cabinet, locate the four
mounting holes on the outer casing. Align
these four holes with those on the blower
bracket assembly. Attach blower bracket as-
sembly to the outer casing with 4 - #10 screws
provided (see Figure 15, page 13).
Shoulder
Screws
7. Route the wire harness through the hole to the
left side of heat deflector. Pull wire harness
through lower opening to the left of the blower
control shield. (see Figure 15, page 13).
Figure 14 - Installing Snap Bushings
www.desatech.com
CAUTION: Label all wires
CAUTION: Verify proper op-
Blower
Control
Shield
Snap
Bushing
113897-01E

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cf26nra

Table of Contents