CS-V18B KP CU-V18BK P5 / CS-V24BK P CU-V24B KP5
230V
Indoor wet
bulb temp.
17.0°C
19.0°C
19.5°C
22.0°C
230V
Indoor wet
bulb temp.
17.0°C
19.0°C
19.5°C
22.0°C
TC - Total Cooling Capacity (kW)
SHC - Sensible Heat Capacity (kW)
IP - Input Power (kW)
30
TC
SHC
IP
TC
5.65
4.29
2.03
5.28
5.70
6.21
4.49
2.07
5.80
6.77
4.65
2.11
6.32
30
TC
SHC
IP
TC
6.97
5.29
2.56
6.52
7.03
7.66
5.54
2.61
7.16
8.34
5.74
2.66
7.80
Outdoor Temp. (°C)
35
40
SHC
IP
TC
SHC
4.11
2.19
4.91
3.95
2.22
4.31
2.23
5.40
4.15
4.48
2.27
5.88
4.32
Outdoor Temp. (°C)
35
40
SHC
IP
TC
SHC
5.07
2.76
6.06
4.87
2.80
5.32
2.81
6.66
5.12
5.52
2.86
7.25
5.33
48
46
IP
TC
SHC
IP
2.34
4.47
3.75
2.52
2.38
4.91
3.95
2.57
2.43
5.35
4.12
2.62
46
IP
TC
SHC
IP
2.95
5.51
4.63
3.18
3.01
6.05
4.87
3.24
3.06
6.59
5.08
3.30