Panasonic CS-V18BKP Service Manual page 34

Room air conditioner
Hide thumbs Also See for CS-V18BKP:
Table of Contents

Advertisement

CS-V18B KP CU-V18BK P5 / CS-V24BK P CU-V24B KP5
10.2.5. CONNECT THE CABLE TO THE
INDOOR UNIT
1. The inside and outside connecting cable can be connected
without removing the front grille.
2. Connecting cable between indoor unit and outdoor unit
shall be approved polychloropre ne sheathed 3 (C18BK,
C24BK, XC24BK, V18BK, V24BK) or 5 (A18BK, A24BK,
W18BK, W24BK) × 2.5 mm
245 IEC 57 or heavier cord.
• Ensure the color of wires of outdoor unit and the
terminal Nos. are the same to the indoor's respectively.
• Earth lead wire shall be longer than the other lead wires
as shown in the figure for the electrical safety in case of
the slipping out of the cord from the anchorage.
• Secure the cable onto the control board with the holder
(clamper).
INSTALLATION OF AIR PURIFYING FILTERS
1. Open the front panel.
2. Remove the air filters.
3. Put air purifying filters (left) and solar refreshing deodorizing
filter (right) into place as shown in illustration below.