Bosch SST150-40 Installation And Operating Manual page 12

Indirect fired water heaters
Hide thumbs Also See for SST150-40:
Table of Contents

Advertisement

Installation & Operating Manual
AIR
SEPARATOR
SYSTEM SUPPLY
SENSOR
TO
SYSTEM
SYSTEM
BALL VALVE
PUMP
(TYPICAL)
EXPANSION
TANK
Figure 3-4 Multiple tank connections in reverse return
NOTICE:
Please note that these illustrations are
meant to show system piping concept only,
the installer is responsible for all equipment
and detailing required by local codes.
1 2 |
AIR
SEPARATOR
GB 142
BOILER
DHW
TANK
PUMP
Y-STRAINER
(RECOMMENDED)
DRAIN
POINT
HOT
WATER
OUT
FROM
SYSTEM
SST series tank
Indirect Fired Water Heaters Installation and Operating Manual
ANTI-SCALD
MIXING VALVE
COLD
WATER
IN
RECIRCULATION
PUMP
CHECK VALVE
PRESSURE
RELIEF VALVE
(TYPICAL)
TANK SENSOR
(TYPICAL)
DRAIN
( FIELD SUPPLY )
SST series tank

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sst300-80Sst250-65Sst450-119

Table of Contents